ARMA-C125-CRM
26
MENU (SCREEN) PAGE
#1
NOTE: Commands ‘F5’, ‘F6’, ‘F7’ & ‘F8’ require that the unit to be in REMOTE mode. See
Figure 5
: Page #1 of the Communication Program
F1 - Queries the unit for ID and serial number.
F2 - Queries the unit for LEDs information. These are the digital outputs of the unit, that
may be used to light LEDs. After disregarding the header, following the ‘L’ the bytes
1.
‘1’ - The unit is powered. (Will always be ‘1’)
2.
‘1’ - RF output power detected.
3.
‘1’ - Alarm condition exists
4.
‘1’ - Fault condition exists
5.
‘1’ - This unit is connected to the antenna (ON-LINE)
6.
‘1’ - This unit is connected to an RF load (STDBY)
7.
‘1’ - The unit shutdown by operator (MUTE)
8.
- No info
9.
‘1’ - unit under remote control / ‘0’- LOCAL control
10.
‘S’
11.
‘1’ - A message is available / ‘0’- no messages
Copyright 1995.
F1
ID&Ser
F2
Leds
F3
Messag
F4
Param
F5
Reset
F6
MUTEon
F7
MUTEof
F8
Atten
F9
Unit#
F0
More
ADVANTECH - Advanced Microwave Technologies, Inc.
Address
: 0
Leds info
: >00AL110010 011 S001 00#K
Message : >00AM#P
Parameters : >00AP A0.0 C35.8 M20.0 O43.1 R17.3 TM49.2 TS28.6
PAGE - 1 - PROTOCOL: ADV, 9600, E Rev 1.00
Alt-X to exit