1.1   

Introduction

 

 

AVAS-402  is  a  video  recorder  that  supports  multi-channel 
recording  at  one  time.  It  has  video  capture  I/O,  video  display  I/O 
and other I/Os. Video capture I/O includes HDMI, which supports 
video  data  up  to  4k  resolution  and  @60  frame  rate,  as  well  as 
Y/PbPr,  CVBS,  S-Video,  SDI,  HDMI,  DVI-I  which  supports  video 
data  up  to  FHD  resolution  and  @60  frame  rate.  There  could  be 
three I/Os for video display: DVI, Display Port, and HDMI. Dual-link 
2560 x 1600 resolution and @60 frame rate is supported for DVI-D, 
while both HDMI and Display Port support maximum resolution at 
4096x2160 (4K)@60Hz frame rate 
 
Other I/Os include RJ-45 ports, USB 3.0 ports and USB 2.0 ports, 
RS-232 port, and Audio out/in 3.5mm stereo jack connectors. 
    With  the  SATA  3.0  interface,  the  AVAS-402  is  a  user-friendly 
computer  that  system  integrators  can  use  this  highly  integrated 
multimedia  system  to  easily  implement  into  your  applications. 
Apart  from  that,  AVAS-402  provides  SDKs  and  APIs  for  system 
integrators  to  program their  video  applications  efficiently. In  other 
chapters,  the  SDKs  and  APIs  provided  will  be  described  in  more 
detail. 

 

 
 

Intended use 

- AVAS-402 is intended to serve as a medical video 

recorder  for  integration  with  hospital  systems.  AVAS-402  is 
designed  for  general  purpose  used  in  medical  image  or  video 
related application in the hospital environment, for data collection 
and for dis-playing information via connecting a display.

 

 

It should not be used as a life-support system.

 

 

The latest version of this user manual is available 
for download from 
http://support.advantech.com.tw/support/

 

 

1.2   

Specifications 

 

System 

CPU 

Intel® Core™ i7-7700 3.6GHz 

Memory 

16GB, Up to 32GB DDR4 2133MHz 

Storage 

1TB, based on customers’ requirement 

System input 
rating

 

Input Voltage 

100-240 AC 

Video 

Input Resolution   

Up to 4K   

Output Resolution 

Up to 4K   

Compression 
Format 

MPEG2 H.264, H265 

Audio 

Audio 

2 (Mic-in/ Line-out) (Mic-in could be configured as "Line-in" 

under Win OS.) 

IO Port   

Video Display 

1 x 

DVI, 

1 x 

Display Port, 

1 x 

HDMI (can be optional)

 

Video Capture 

4Kp60: 

1 x 

HDMI 

 

FHD (max): Y/PbPr, CVBS, S-Video, SDI, HDMI, DVI-I (can be 
optional)

 

Summary of Contents for AVAS-402

Page 1: ...AVAS 402 Medical Video recorder...

Page 2: ...ions 1 Strictly follow these Instructions for Use please read these safety instructions carefully 2 Please keep this User Manual for later reference any use of the product requires full understanding...

Page 3: ...time disconnect it from the power source to avoid damage by transient over voltage Caution Do not leave this equipment in an uncontrolled environment where the storage temperature is below 20 C 4 F o...

Page 4: ...standards EN 60601 1 IEC 60601 1 Medical electrical equipment Part 1 General requirements for safety EN 60601 1 1 IEC 60601 1 1 Medical electrical equipment Part 1 1 General requirements for safety Co...

Page 5: ...matches the voltage of the power outlet which has been approved and complies with the safety standard of your particular country Note Environmental protection Follow national requirements to dispose o...

Page 6: ...ISO 7010 M002 Follow instructions for us...

Page 7: ...erated in a residential environment This equipment generates uses and can radiate radio frequency energy If not installed and used in accordance with this user manual it may cause harmful interference...

Page 8: ...ease have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application so...

Page 9: ...DKs and APIs for system integrators to program their video applications efficiently In other chapters the SDKs and APIs provided will be described in more detail Intended use AVAS 402 is intended to s...

Page 10: ...Class B certified Environment Temperature 0 40 C Operating 10 50 C Storage Transportation Humidity 10 90 40 C non condensing Operating 5 90 non condensing Storage Transportation Pressure 700 1060 hPa...

Page 11: ...Figure 1 2 AVAS 402 Front Panel 1 Power button blue light 2 USB 3 0 Figure 1 3 AVAS 402 Rear Panel 3 RS232 4 DVI D 5 Display Port 6 HDMI 7 USB 2 0 8 USB 3 0 9 RJ 45 10 Headphone 11 MIC...

Page 12: ...Suggested cleaning detergent 1 10 Sodium HyAVAShlorite 90 water solution 2 A solution of 90 water 6 benzyl alcohol and 3 Hydrogen Peroxide 3 Glutaraldehyde 2 4 Caution Do not immerse or rinse the AVAS...

Page 13: ...data in the memory units of the storage...

Page 14: ...pany shall translate and review by the manufacturer see SOP document number SOP_Writing_Guidelines ed 3 Experience Mentally and physical competent specific medical training to understand basic knowled...

Page 15: ...ed at the rear cover including Display port COM port HDMI port DVI D port Ethernet ports USB ports and so on Apart from the I O ports shown in below fig 2 2 additional I O ports are also included not...

Page 16: ...8 USB 3 0 X 6 9 Lan Ports RJ 45 X 2 10 Audio out Headphone 11 Audio in MIC NOTE Equipotential terminal need link to hospital ground earth system before system boot to protect operator and system...

Page 17: ...female end of the power cord to the 3 pin AC male plug of AVAS 402 2 Connect the 3 pin male plug of the power cord to an electrical outlet Figure 2 7 Connecting the power cord 2 2 2 Connecting the Gr...

Page 18: ...t POST If an error occurs an error message will be displayed on screen and you will be prompted to run the setup program 2 4 Installing System Software Recent releases of operating systems from major...

Page 19: ...g system version application software etc A complete description of the problem The exact wording of any error messages Symptoms photo or video if available Guidance and Manufacturer s Declaration Ele...

Page 20: ...ters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the equation in the table above applicable to the frequency of the transm...

Page 21: ...in power quality should be Surge line s line s that of a typical commercial or IEC 61000 4 5 2 kV line s to 2 kV line s to hospital environment earth earth 5 UT 95 dip 5 UT 95 dip in in UT for 0 5 cyc...

Page 22: ...e d 1 2 P d 1 2 P 80 MHz to 800 MHz Conducted 3 Vrms RF d 2 3 P 800 MHz to 2 5 GHz 150 kHz to 80 IEC 61000 4 MHz Vrms 6 where P is the maximum output Radiated RF 3 V m V m power rating of the transmit...

Page 23: ...nment due to fixed RF transmitters an electromagnetic site survey should be considered If the measured field strength in the location in which AVAS 402 is used exceeds the applicable RF compliance lev...

Page 24: ...want to remove install any parts 3 2 Thermal The vent hole on the rear cover of AVAS 402 as well as system fans CPU fan function as a cooling air flow inlet and outlet These air inlets and outlets tra...

Page 25: ...this product through the openings in the case Doing so may be dangerous and result in fire or a dangerous electric shock Never place anything on system case before turning off the computer Never turn...

Reviews: