IPC-613 User's Manual
7
2.5 Temperature Setting
If the chassis interior temperature exceeds 65
o
C (149
o
F) (default setting), the LED changes color from
green to red. There will be audio alarm as well. The LED remains red until the temperature goes below
63
o
C.
Temperature also can be selected (SW1) on the alarm board inside the chassis:
SW1
1
2
TEMP
OFF
OFF
65
o
C
OFF
ON
55
o
C
ON
OFF
70
o
C
ON
ON
75
o
C
Figure 2-5: Temperature Setting