 IPC-622MS   User's Manual   1

Chapter 1  General Information

1.1  Introduction

The IPC-622MS is a 20-slot, 19" rackmount industrial PC chassis with 400-watt AC-DC power supply.
IPC-622MS features an advanced fault detection and alarm notification system to monitor its own

hardware status, including overheating and fan-failure problems. It is dangerous and will cause a lot of

loss if your PC system shuts down without any warning in advance. IPC-622MS , the fault resilient IPC,

is designed to prevent from this situation to be more relibile.
The IPC-622MS will withstand shock, vibration, dust and a wide range of operating temperatures in

harsh environments. The chassis is positively pressurized by six filtered push-pull cooling fans to exclude

dust and dirt. A lockable door protects drives and switches from tampering and particles.

1.2  Specifications

General

•

Construction

: Heavy-duty steel

•

Disk drive capacity

:  Six  3.5" disk drives

•

Cooling system

: Four 49 CFM cooling fan (flow in) in front and two 49CFM coolomg fans (flow

out) in rear panel  with an air filter
•

Controls

: Power On/Off switch, CPU reset and alarm reset button are protected by a lockable door

•

Indicators

: LEDs for power On/Off and HDD activity. Bi-color LEDs(green and red) for fan failure

failure and overheating
•

Speaker

: One 8 ohm / 0.2Watt speaker, volumn control on board

•

Dimensions

: 19" (W) x 10.5" (H) x 18" (D)

                       482mm(W) x 267mm(H) x 457 mm(D)
•

Weight

: 66 lb (30 Kg)

•

Paint color:

 Pantone 414U

Passive Backplane (PCA-6119P17)

•

Slots

: 17PCI / 1PICMG -slot

•

PC board

: 4-layer PCB with ground and power planes for reduced noise and lower power

supply impedance

•

Indicators

: LEDs for +5 V, -5 V, +12 V and -12 V

All manuals and user guides at all-guides.com

Summary of Contents for IPC-622MS

Page 1: ...IPC 622MS Industrial PC Chassis All manuals and user guides at all guides com...

Page 2: ...ual is intended to be accurate and reliable However Advantech Co Ltd assumes no responsibility for its use nor for any infringements of the rights of third parties which may result from its use Acknow...

Page 3: ...able wiring schematic 6 2 6 Cable wiring schematic 7 2 7 The rubber for card vibration damped 8 Chapter 3 Fault Resilient Function 9 3 1 Introduction 9 3 2 Fault detection and alarm notification 9 3 3...

Page 4: ...e dust and dirt A lockable door protects drives and switches from tampering and particles 1 2 Specifications General Construction Heavy duty steel Disk drive capacity Six 3 5 disk drives Cooling syste...

Page 5: ...Operating temperature 41 to 95o F 5 to 35o C Relative humidity 10 to 85 35o C Storage Temperature 13 to 140o F 25 to 60o C 0 to 95 relative humidity Safety UL C UL Listed EMI FCC Class A Fault Detect...

Page 6: ...system status On the rear panel there is a Ground point earthing point located on the bottom right hand corner This provides an earth for the whole system and is attached via a screw WARNING Disconnec...

Page 7: ...e filter The filter is located on the front upper chassis Under continuous use the filter should be replaced about once a month To replace the filter refer to figure 2 4 below and do as the following...

Page 8: ...sides Remove the four outer screws which mount the shock resistant drive bay to the chassis See figure 2 4 below 2 Slide the drive bay toward the front chassis and lift it free of the chassis Remove t...

Page 9: ...etails of the setting Position 1 ID BIT 3 OPEN OPEN OPEN OPEN Position 2 ID BIT 2 OPEN OPEN OPEN CLOSE Position 3 ID BIT 1 OPEN CLOSE CLOSE OPEN Position 4 ID BIT 0 CLOSE OPEN CLOSE OPEN Position 5 AU...

Page 10: ...IPC 622MS User s Manual 7 2 6 Cable wiring schematic The following picture is the cable schematic for IPC 622MS 2 7 Cable schematic All manuals and user guides at all guides com...

Page 11: ...mped The IPC 622MS uses two rubbers on the inside cover of the chassis to ensure the plug in cards are located securely It also offers protection against shock and vibration 2 8 The rubber for cards v...

Page 12: ...ion The IPC 622MS monitors system hardware for fan failure and high temperature within the chassis Fault conditions are Fan failure Either of the four cooling fans fails High Temperature If the chassi...

Page 13: ...eset However the alarm indicator will stay red until the fault condition is resolved 3 2 Controls 3 4 Overheating Sensor There is a small PC board the Over Temp board installed on the left interior of...

Page 14: ...IPC 622MS User s Manual 11 Unit mm Appendix A Passive Backplane PCA 6119P17 17PCI 1PICMG slot Backplane Dimension 420 x 200 mm All manuals and user guides at all guides com...

Page 15: ...12 IPC 622MS User s Manual Appendix B Exploded Diagram All manuals and user guides at all guides com...

Page 16: ...IPC 622MS User s Manual 13 All manuals and user guides at all guides com...

Page 17: ...l cautions and warnings on the equipment should be noted 11 If the equipment is not used for a long time disconnect the equipment from mains to avoid being damaged by transient overvoltage 12 Never po...

Page 18: ...quipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation...

Reviews: