2 IPC-622MS User's Manual
1.3 Dimensions
Unit = mm
400-watt AC-DC Power Supply
Output rating
: 400 watts (Max.)
Input voltage
: 100 to 130 V
AC
or 200 to 260 V
AC
@ 47~63 Hz, switchable
Output voltages
: +5 V @ 40 A, +12 V @ 20 A, -5 V @ 0.5 A, -12 V @ 1 A
Maximun power output of all outputs combined must not exceed 400watts
Minimum load:
+5 V @ 3 A, +12 V @ 0.5 A
MTBF
: 150,000 hours
Safety
: UL/CSA Approved
Environmental Specifications
Operating temperature
: 41 to 95
o
F (5 to 35
o
C), Relative humidity : 10 to 85% @ 35
o
C
Storage Temperature
: -13 to 140
o
F (-25 to 60
o
C), 0 to 95% relative humidity
Safety
: UL / C-UL Listed
EMI
: FCC Class A
Fault Detection and Alarm Notification
Fan failure:
If either of the four cooling fans fails, the FAN LED changes color from green to red
also audio alarm. The dedicated LED remains red for failed fan set until it fixed.
High Temperature:
If the chassis interior temperature exceeds 55
o
C(131
o
F)(standard setting), the
LED changes color from green to red also audio alarm.