Web GUI Monitoring & Control
Figure 4.8: SBM-75 Status Window
This page will give a summary of the unit status.
4.5.1
Status monitoring
Table 4.2: Status monitoring values
FPGA
Field Programmable Gate Array have programmed correctly
Self Test
Diagnostic check passed
Input
This will indicate locked if the data rate Is valid otherwise
unlocked
will be reported.
Output Power
This should always read calibrated. If it reads
uncalibrated
then
please contact support
Programmed Baud Rate This is the programmed baud rate. If the unit was programmed
with a bit rate this is the calculated rate.
Actual Baud Rate
The Actual Baud rate can be proportional to the incoming bit
rate and hence may be different to the programmed rate.
Board Temperature
This is the temperature as measured on the modulator card.
Core1 Temperature
This is the temperature on the silicon surface of the FPGA.
Clock Source
Internal: High stability OCXO used for reference
External: External 10Mhz reference used
Hold: Stores the frequency of the 10MHz reference.
Ext Clock Source
Indicates if the External 10MHz reference is locked.
Ref. In state
Signal / No Signal. Is there any signal on the reference?
CCM State
Input
N/A: Input not used in this mode
Off: Input disabled
Main: Main input in use
Spare: Redundant input in use
Overflow
X
: Input rate exceeded
√
: Input rate below limit
Sync
X
: Sync not detected
√
: Sync Detected
Rate Rate
in
kb/s
4-10
SBM75e Series Modulator Installation and Operation Manual
Summary of Contents for L-Band Satellite Modulator
Page 14: ...Getting Started 1 8 SBM75e Series Modulator Installation and Operation Manual...
Page 45: ...Front Panel Monitoring Control SBM75e Series Modulator Installation and Operation Manual 3 15...
Page 73: ...Web GUI Monitoring Control 4 28 SBM75e Series Modulator Installation and Operation Manual...
Page 78: ...Technical Specification SBM75e Series Modulator Installation and Operation Manual A 5...