Web GUI Monitoring & Control
4.8.9
User-E
This is identical to the User-1 mode except a 16 digit hex value is required for the ESW and a 14
digit hex value is required for the injected ID. The even key is the same key as used for BISS-E.
4.8.10
BISS Insertion Period
This sets the frequency that the Program Association Table (PAT), Programme Map Table (PMT)
and Conditional Access Table (CAT) will be inserted into the stream. The default is 200 ms and this
value should be suitable in most circumstances.
4.8.11
BISS Active Key
When the BISS Mode is either Mode-E or ODD/EVEN-E or User-E then the BISS Active Key can be
selected. This determines which key shall be used.
4.8.12
BISS Status
Table 4.3: BISS Status
Property
Status
Description
State
Uninitialized
Error condition, BISS failure
Idle : illegal in
this mode
BISS cannot be used in this mode
Idle
BISS is turned off
Configured
BISS is active, this will include BISS-0 Mode
Extraction
Active
SI extraction is active
Inactive
no SI extraction
Keys
OK
Valid keys present, this should always be OK
stream info
PAT not found
The PAT is not detected, critical failure
Corrupted tables
At least one of the PMT listed in the PAT cannot be extracted or
At least one of the PMT has a bad structure or a CRC error
No CAT
detected
CAT is not found, this can be normal
OK
Transport stream is OK
processing
Ciphering
The block cipher is engaged and ciphering
Unciphering
The block cipher is engaged and deciphering
None
The block cipher is not engaged
PMT info
Too many
PMT(s)
too many PMT(s) are received for the playout RAM (overflow)
Incorrect PMT(s)
A PMT cannot be modified to add/remove BISS SI (PIDs listed in the PMT
would not be ciphered/deciphered)
Missing PMT(s)
A PMT listed in the PAT could not be retrieved
OK
All is OK
4-26
SBM75e Series Modulator Installation and Operation Manual
Summary of Contents for L-Band Satellite Modulator
Page 14: ...Getting Started 1 8 SBM75e Series Modulator Installation and Operation Manual...
Page 45: ...Front Panel Monitoring Control SBM75e Series Modulator Installation and Operation Manual 3 15...
Page 73: ...Web GUI Monitoring Control 4 28 SBM75e Series Modulator Installation and Operation Manual...
Page 78: ...Technical Specification SBM75e Series Modulator Installation and Operation Manual A 5...
Page 90: ...Glossary B 12 SBM75e Series Modulator Installation and Operation Manual...