86
C.7 Control Register — BASE+6 and BASE+7
The write-only register BASE+6 and BASE+7 allows users to set an
A/D trigger source and an interrupt source.
Table C-6: Control Register
Write
A/D Status Register
Bit #
7
6
5
4
3
2
1
0
BASE + 7
CAL
BASE + 6
AD16/12
CNT0
ONE/FH
IRQEN
GATE
EXT
PACER
SW
SW
Software trigger enable bit
1
enable
0
disable.
PACER
Pacer trigger enable bit
1
enable
0
disable.
EXT
External trigger enable bit
1
enable;
0
disable.
Note:
You cannot enable SW, PACER and EXT concurrently.
GATE
External trigger gate function enable bit.
0 Disable
1 Enable
IRQEN
Interrupt enable bit.
Summary of Contents for MIC-3716
Page 2: ...ii This page is left blank for hard printing...
Page 6: ...vi This page is left blank for hard printing...
Page 8: ...viii Table E 2 D A binary code table 117...
Page 11: ...1 Introduction 1 CHAPTER...
Page 17: ...7 Fig 1 1 Installation Flow Chart...
Page 21: ...11 Installation and Configuration CHAPTER 2...
Page 40: ...30 This page is left blank for hard printing...
Page 41: ...31 Signal Connections CHAPTER 3...
Page 44: ...34 Fig 3 1 I O connector pin assignments for the MIC 3716...
Page 50: ...40...
Page 54: ...44 This page is left blank for hard printing...
Page 55: ...45 Software Programming Overview CHAPTER 4...
Page 60: ...50 This page is left blank for hard printing...
Page 61: ...51 Calibration CHAPTER 5...
Page 77: ...67 Appendixes...
Page 81: ...71 Appendix B Block Diagrams...
Page 82: ...72 This page is left blank for hard printing...
Page 120: ...110 This page is left blank for hard printing...