Note:
The IPMC firmware provides an OEM IPMI command to allow users to switch the
IMPC/FPGA connected NC-SI interface between the front panel LAN IO and the Base
interface LAN controllers and also to select between the 2 IO and BI connections. See
below the description of the corresponding OEM commands:
LAN controller interface selection
The BMC firmware provides an OEM IPMI command to allow users to switch the BMC
connected NC-SI interface between two front panel LAN IO RJ-45 connector and the
Base interface (0/1). These commands can be used to read out the actual selected
IPMI-over-LAN / Serial-over-LAN interface and to change the selection.
LAN controller interface selection settings:
00h: Front panel LAN IO
01h: LAN BI (default)
Read LAN Interface selection:
Response:
Change LAN Interface selection:
Response:
LAN controller channel selection and priority
In addition to the selected LAN controller interface, users may need to configure each
single LAN controller channel (port) as dedicated NC-SI interface to the BMC.
Additional OEM commands for the configuration of the NC-SI LAN controller channel
selection and priority are provided to allow a flexible configuration.
39 28 00
ipmitool raw 0x2e
0x40
0x39 0x28 0x00
0x04 0x00 <setting>
39 28 00
<setting>
ipmitool raw 0x2e
0x41
0x39 0x28 0x00
0x04 0x00
Summary of Contents for MIC-5332
Page 7: ...This page is left blank intentionally ...
Page 10: ...Chapter 1 Product Overview This chapter briefly describes the MIC 5332 ...
Page 15: ...Chapter 2 Board Features This chapter describes the MIC 5332 hardware features ...
Page 43: ...Figure 3 10 Jumper Locations JP1 JP5 JP6 ...
Page 44: ...Chapter 4 Hardware Management This chapter describes the IPMC firmware features ...
Page 105: ... root localhost ipmitool raw 0x2E 0x40 0x39 0x28 0x00 0x03 0x01 section ...
Page 108: ...Appendix A IPMI PICMG Command Subset Supported by IPMC ...
Page 120: ...33 48V_A 48V input feed A 34 48V_B 48V input feed B ...