PCI-1243U User Manual
16
2.4 Jumper Settings
JP1 has a convenient design that enables storage of motion register
configurations into CPLD, so the configurations can be kept even when
the PC power is off. The factory default is in “Normal” position (1-2 pin
shorted), which means the register setting will disappear after a power
reset. You can move JP1 to the “Keep” position (2-3 pin shorted) to store
configurations.
JP11 and JP12 set the polarity for Emergency stop and Tri_STA pin
respectively. When the jumper is set to pin 2 and 3 (factory default), the
input channel is in 'normally open'. When the jumper is set to pin 1 and 2,
the input channel is 'normally closed'.
Figure 2.10: EMG / Tri_STA Test Configuration
Table 2.1: JP1 Settings
Normal (reset register) (default).
Keep (store configurations)
Note:
The factory default is Normally Open.
V = 12 ~ 24 V DC
Imax = 10 mA
Normally
Open
+
-
Normally
Closed
(4.7k / 1 W)
EMG/Tri-STA
EXT_COM
V