Dual rate operation (ramping down). Frequency ramps down to the level
of the FL.
*
0 (no output of INT signal at stop)
1 (output of INT signal at stop)
Decelerating stop (reset command is required after stop). Frequency
ramps down to the rate of the FL, then stops.
Reset command. This stops pulse generation under any condition. If you
start with the start-command, be sure to reset with the reset command
before the next start. This gives INT signal and the start command has to
be reset. Contents in registers R0 through R7 are not changed.
*
0 (no output of INT signal at stop)
1 (output of INT signal at stop)
1: The start command is set to standby. It will wait for the external start
trigger to start motion.
0: Software start command will start motion immideately.