65
Chapter 4
4.7.3 Constant Speed Preset Model
t
f
Execute the reset
command
Effect the ramping
mode and select the
direction
Select the counter
Set the number of
output pulse
Start
The status (0)is read
Command buffer <- 00001000(08H)
For(+)direction: command buffer <- 01000100(44H)
For(-)direction: command buffer <- 01001100(4CH)
Command Buffer <- 10000000(80H)
Register bits 23-16 <- data, high-order 8 bits
Register bits 15-8 <- data, mid-order 8 bits
Register bits 7-0 <- data, low-order 8 bits
Wait for 400ns
The order is important!
Command Buffer <- 00010101(15H)
Waiting for completion of operation
Stop at pre-
set count
Bit 3=0?
YES
Completion of
operation
Ramp down at
set point
NO
Summary of Contents for PCI-1243U