69
Chapter 4
4.7.7 Constant Speed Origin Return Model
t
f
Execute the reset
command
Effect the origin return
mode and select the
direction
Enter the start
command
Command buffer <- 00001000(08H)
For(+)direction: command buffer <- 01000001(41H)
For(-)direction: command buffer <- 01001001(49H)
For FH: Command Buffer <- 00010000(10H)
For FL: Command Buffer <- 00010001(11H)
Stop by origin
switch = ON
The status (0)is read
Bit 3=0?
YES
Completion of
operation
NO
When the ORG signal is ON,pulse output stops
and bit 3 of status 0 becomes 0