67
Chapter 4
4.7.5 Constant Speed Continuous Mode
t
f
Execute the reset
command
Effect the manual mode
and set the direction
Enter the start
command
Enter the immediate
stop command
Command buffer <- 00001000(08H)
For(+)direction: command buffer <- 01000000(40H)
For(-)direction: command buffer <- 01001000(48H)
For FL: Command Buffer <- 00010000(10H)
For FH: Command Buffer <- 00010001(11H)
Immediate
stop
command
Completion of
operation
Command buffer <-00001000(08H) (reset command)
Summary of Contents for PCI-1243U
Page 1: ...PCI 1243U 4 Axis Stepping Motor Control Card User Manual ...
Page 8: ...PCI 1243U User Manual viii ...
Page 14: ...PCI 1243U User Manual 6 ...
Page 35: ...27 Chapter3 Figure 3 8 Point to Point Movement ...
Page 38: ...PCI 1243U User Manual 30 ...
Page 80: ...PCI 1243U User Manual 72 Appendix A Diagrams A 1 Jumper and Switch Layout ...
Page 82: ...PCI 1243U User Manual 74 ...
Page 88: ...PCI 1243U User Manual 80 ...