PCI-1243U User Manual
68
4.7.6 High Speed Continuous Mode
t
f
Execute the reset
command
Effect the manual
mode and select the
direction
Enter the start
command
Enter the deceleration
stop command
The status (0)is read
Command buffer <- 00001000(08H)
For(+)direction: command buffer <- 01000000(40H)
For(-)direction: command buffer <- 01001000(48H)
For FH: Command Buffer <- 00010101(15H)
Command Buffer <-
00011100(1CH)
Waiting for deceleration stop
Stop after
deceleration
Bit 3=0?
YES
Completion of
operation
Deceleration-
stop command
NO