SmartFlex SR310
7. Technical Parameters
7.1
Basic parameters
SmartFlex Router
Temperature range
Operating
Storage
-40
◦
C to +70
◦
C
-40
◦
C to +85
◦
C
Cold start
-15
◦
C
-20
◦
C
Data transfers via mobile network are available
immediately
Data transfers via mobile network are available
approximately in five minutes after the start of
the router. Everything else is functional imme-
diately.
Humidity
Operating
Storage
0 to 95 % relative humidity non condensing
0 to 95 % relative humidity non condensing
Altitude
Operating
2000 m / 70 kPa
Degree of protection
IP30
Supply voltage
10 to 60 V DC
Battery for RTC
CR1225
Consumption
Idle
Average
Peak
Sleep mode
2.5 W
4 W
11 W
10 mW
Dimensions
55 x 97 x 125 mm (DIN 35 mm, EN 60715)
Weight
Plastic box
Metal box
approximately 170 g (depends on interface)
approximately 375 g (depends on interface)
Antenna connectors
2x SMA – 50
Ω
1x R-SMA – 50
Ω
(je-li osazen WiFi modul)
User interface
2x ETH
USB
I/O
Micro SD
Ethernet (10/100 Mbps)
USB 2.0
6-pin panel socket
SDHC, SDXC
Table 29: Basic parameters
42