Ethernet Ports (ETH0 and ETH1)
The panel socket RJ45 is used for this interface. The isolation barrier of the Ethernet signal
ports against the ground is 1500 V.
Pin
10base-T & 100base-T
PoE (Mode B)
1
Tx+ (Transmit Data+)
—
2
Tx- (Transmit Data-)
—
3
Rx+ (Receive Data+)
—
4
—
PoE + (positive pole)
5
—
PoE + (positive pole)
6
Rx- (Receive Data-)
—
7
—
PoE - (negative pole)
8
—
PoE - (negative pole)
Table 13: Ethernet connector pinout
Figure 18: Ethernet connector
The crossover UTP cable (Ethernet cable) plugs into the RJ45 connector labeled as ETH0
or ETH1 (see the figure below).
Figure 19: Connection of Ethernet cable
The insulation strength of Ethernet ports from each other and from the rest of the router
(grounding) is dependent on the router version:
Router Version
Insul. Strength from Router
Insul. Strength between Ports
Without PoE
1.5 kV
1.5 kV
PoE PD
1.5 kV
none
PoE PSE
none
none
Table 14: Insulation strength of Ethernet ports
22