CLASSIFICATION:

Supply by Class I adapter

No applied part

Continuous Operation

Not AP or APG category

18.

Follow the national requirement to dispose unit.

19.

Maintenance: to properly maintain and clean the surfaces, use only the 
approved products or clean with a dry cloth.

20.

Contact information:
No.1, Alley 20, Lane 26, Rueiguang Road Neihu District, Taipei, Taiwan 114, 
R.O.C
TEL: (02)27927818

21.

22.

This equipment shall not be used as a life support system.

23.

Accessory equipment connected to the analog and digital interfaces must be in 
compliance with the respective nationally harmonized IEC standards (i.e. IEC 
60950 for data processing equipment, IEC 60065 for video equipment, IEC 
61010-1 for laboratory equipment, and IEC 60601-1 for medical equipment.) 
Furthermore all configurations shall comply with the system standard IEC 
60601-1-1. Anyone who connects additional equipment to the signal input part 
or signal output part is configuring a medical system, and is therefore, responsi-
ble that the system complies with the requirements of the system standard IEC 
60601-1-1. The unit is for exclusive interconnection with IEC 60601-1 certified 
equipment in the patient environment and IEC 60XXX certified equipment out-
side of the patient environment. If in doubt, consult the technical services 
department or your local representative. 

24.

User not to connect SIP/SOPs and the patient at the same time.

25.

The sound pressure level at the operator's position according to IEC 704-1:1982 
is no more than 70dB (A).

DISCLAIMER: This set of instructions is given according to IEC 704-1. Advantech
disclaims all responsibility for the accuracy of any statements contained herein.

Note!

Attention, consult ACCOMPANYING DOCUMENTS.

Summary of Contents for UTC-W101E

Page 1: ...User Manual UTC W101E...

Page 2: ...rotection against harmful interference in a residential installa tion This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruct...

Page 3: ...e have the following information ready before you call Product name and serial number Description of your peripheral attachments Description of your software operating system version application softw...

Page 4: ...nto an opening This may cause fire or electrical shock 13 Never open the equipment For safety reasons the equipment should be opened only by qualified service personnel 14 If one of the following situ...

Page 5: ...equipment Furthermore all configurations shall comply with the system standard IEC 60601 1 1 Anyone who connects additional equipment to the signal input part or signal output part is configuring a me...

Page 6: ...UTC W101E User Manual vi...

Page 7: ...Description 5 2 1 General Specifications 6 2 1 1 Standard PC Functions 6 2 1 2 Power Environmental 6 2 2 Mechanical Specifications 7 2 2 1 Mechanical Specifications Terminal 7 2 2 2 Mechanical Drawing...

Page 8: ...UTC W101E User Manual viii...

Page 9: ...Chapter 1 1 Introduction This Chapter briefly introduces the UTC W101E product...

Page 10: ...1 wide format resistive touch based LCD panel Not only is it cost effective but it s also a versatile solution designed to meet the vast demand emerging from the market Hot keys on the bezel provide I...

Page 11: ...3 UTC W101E User Manual Chapter 1 Introduction 1 2 System Configuration The following diagram is a block drawing of the UTC W101E based on a hospital bedside environment Button I O arrangement...

Page 12: ...UTC W101E User Manual 4...

Page 13: ...Chapter 2 2 Hardware Description This Chapter describes the hard ware features of the UTC W101E...

Page 14: ...N Marvell Yukon 88E8071 PCI E Gigabit Ethernet controllers x 2 Universal serial bus USB port 4 ports for external I O Mini PCI E bus expansion slot Accepts one mini PCI E bus card Storage housing Spac...

Page 15: ...2 1 Mechanical Specifications Terminal System Dimensions 258 W x 199 H x 38 3 D mm Carton Dimensions 320 W x 140 H x 250 D mm Gross Weight 2 0 kg Net Weight 1 8 kg 2 2 2 Mechanical Drawing for Button...

Page 16: ...UTC W101E User Manual 8 2 3 Appearance Front View Terminal Side View Rear View Terminal...

Page 17: ...Chapter 3 3 Design Requirements This Chapter describes the design requirements of the UTC W101E...

Page 18: ...on condensed Safety CE EMI FCC class B approved Vibration 10 18 Hz 1 5 mm peak to peak displacement 18 500 Hz 1 G acceleration 3 2 Reliability MTBF 20 000 hours Touchscreen 1 million touch actuation t...

Page 19: ...11 UTC W101E User Manual Chapter 3 Design Requirements...

Page 20: ...tions are subject to change without notice No part of this publication may be reproduced in any form or by any means electronic photocopying recording or otherwise without prior written permis sion of...

Reviews: