- 19 -
www.advateklights.com
PixLite E4-S Mk3 User Manual V20220819
7 - Operation
7.1 - Start-up
Upon applying power, the controller will quickly begin outputting data to the pixels. If
no data is being sent to the controller, then the pixels will remain turned off until valid
data is received. During live mode, the multi color status LED will be flashing green to
indicate the controller is running and outputting any received data to the pixels.
7.2 - Sending Ethernet Data
Input data is sent from the control PC/server/lighting console to the controller via
Ethernet using a “DMX over IP” protocol such as sACN (E1.31) or Art-Net. This device will
accept Art-Net or sACN data on either Ethernet port.
Sync modes are supported for both Art-Net and sACN. To learn more, refer to the
technical note on synchronous mode here:
www.advateklights.com/knowledge-base
Details of incoming and outgoing packets can be viewed in the Management
Interface.
7.3 - Pixel Outputs
Each of the 4 pixel outputs on the PixLite E4-S Mk3 can drive up to 6 universes of data.
This allows for a total of up to 24 universes of pixel data to be driven out of the one
controller. The number of pixels that can be driven per pixel output will depend on the
configuration, as shown in the table below.
Expanded Mode
Disabled
Enabled
Color Type
RGB
RGBW
RGB
RGBW
Max Pixels per Pixel Output
1,020
768
510
384
Max Total Pixels
4,080
3,072
4,080
3,072
The PixLite must be configured before it can correctly output pixel data. Refer to the
PixLite Mk3 Management Guide for how to configure and patch your pixel outputs.