Advent Instruments Inc.
3. HAL Properties
Name:
ECHO.RINGDISABLE
ID:
206
Type:
Numeric
Description:
Controls the operation of the echo generator during ringing. If set to a non-zero value
(enabled), then all echoes are disabled when ringing is turned on. Once ringing is turned
off, the echoes are re-enabled. If this setting is enabled while ringing is currently active,
it will not have any effect until the ringing is turned off and then turned on again. Note,
this property only has an effect if the ENABLE property is non-zero.
Name:
ECHO.TAPDELAY
ID:
157
Type:
Numeric
Description:
Sets the echo time delay for the echo tap specified by TAPINDEX. The delay value is in
units of ms with a valid range of 0 to 25.
Name:
ECHO.TAPGAIN
ID:
158
Type:
Numeric
Description:
Sets the echo gain (or loss) for the echo tap specified by TAPINDEX. The gain can
range from -100 to +100. A setting of zero turns off the tap. Negative gains invert the
polarity of the echo and gains between less than 1 or more than -1 represent a loss.
Name:
ECHO.TAPINDEX
ID:
156
Type:
Numeric
Description:
Sets which of the three possible echo taps are adjusted using the TAPDELAY and
TAPGAIN properties. The valid range is from 1 to 3.
3.12 FILE Properties
The FILE properties allow access to the non-volatile flash memory contained within the
AI-7280. The flash memory contains a collection of files used to store system level
programs and data along with user programs. Only read access to the flash memory is
allowed by these properties.
Each file is referenced by a 32 bit identification number. Within each file, is a collection
of items, each referenced by an integer value. These items represent file data such as
numeric values or character strings. By using the following properties, the items of a file
can be read.
AI-7280 Programmers Guide - Direct Control
35