3. HAL Properties
Advent Instruments Inc.
3.22 SIGNALIO Properties
The single property in this group sets the gain applied to any signals routed to the rear
panel BNC output connector.
Name:
SIGNALIO.BNCOUTGAIN
ID:
195
Type:
Numeric
Description:
Sets the gain of the BNC output port. It must range between -100 to +100. A negative
value applies a 180 degree phase reversal to the signal. The source of the signal sent to
the BNC output port is determined by the SOURCE.BNCOUT property value.
3.23 SOURCE Properties
The following four properties select what signal source is routed to the signal meter,
signal analyzer, rear panel BNC output, and the phase meter reference channel.
Name:
SOURCE.ANALYZER
ID:
64
Type:
Numeric
Description:
Sets the source of the signal routed to the signal analyzer (DTMF, FSK Decoder,
waveform capture) as follows:
0 = off
1 = telephone interface (both transmit and receive signals)
2 = telephone interface hybrid output (rejects signals transmitted by the AI-7280)
3 = rear panel BNC input connector
4 = tone generators (tone A,B,C,D, MF, and FSK generator, waveform playback)
5 = telephone interface transmit (signal applied to the telephone line by the AI-7280)
54
AI-7280 Programmers Guide - Direct Control