3. HAL Properties
Advent Instruments Inc.
Name:
TELINT.VOLTAGE
ID:
51
Type:
Numeric
Description:
Sets the telephone interface line voltage. The valid range for this property is from 0 to 72
volts.
If the Extended Line Feed Option (AI-E702) is installed, the maximum line voltage
setting is increased to 105 volts.
Name:
TELINT.VRAMPDEST
ID:
61
Type:
Numeric
Description:
This property is used with VRAMPRATE to change the line voltage at a constant slew
rate. VRAMPDEST sets the destination line interface voltage. If a negative voltage is
specified, the line voltage ramps down to zero, toggles the REVERSE property, and then
ramps back up to the destination line voltage.
Name:
TELINT.VRAMPRATE
ID:
62
Type:
Numeric
Description:
Sets the voltage slew rate. The units are in Volts/ms and must be in the range of 0 to 20.
Writing to this property starts the process of ramping the line voltage towards the value
set by VRAMPRATE. When the line voltage reaches the destination voltage this
property value is reset to zero. Writing zero at any time stops the change in the line
voltage.
Note, if high voltage slew rates are specified and a line polarity change is required
(negative VRAMPDEST value), then distortion in the line voltage waveform may be
incurred due to the delay in toggling the polarity reversing relay.
3.27 TIMER Properties
The following timer properties are used to record when events occur or schedule actions
with user programs. All of the timer values are in units of seconds.
Name:
TIMER.FAST
ID:
45
Type:
Numeric
Description:
Fast update timer. This timer counts up every 25.6 microseconds to a maximum of 100
seconds. It can be written to with any value within the range of 0 to 100.
64
AI-7280 Programmers Guide - Direct Control