background image

Battery Monitor (12VDC)

USER MANUAL

PLEASE READ AND UNDERSTAND THIS MANUAL 

COMPLETELY BEFORE USING THIS PRODUCT.

AKEP-BM_01

PATENT APPLIED FOR: 2018322693

V1.7

Summary of Contents for AKEP-BM_01

Page 1: ...Battery Monitor 12VDC USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USING THIS PRODUCT AKEP BM_01 PATENT APPLIED FOR 2018322693 V1 7...

Page 2: ...VIEW 4 4 SETUP INSTRUCTIONS 4 5 WIRING GUIDE 5 6 OPERATION 6 7 UNDERSTANDING THE DISPLAY SCREEN 7 BATTERY 8 MONITOR 9 DISPLAY 9 SYSTEM 10 8 BATTERY MONITOR SETUP 8 9 AUTOMATIC SHUT OFF CONDITIONS 11 U...

Page 3: ...way and understand the hazards involved WARNING Pure and modified sine wave Inverters have their own internal safety shut off electronics All Inverters should be connected directly to the Battery Do N...

Page 4: ...the Auxiliary battery Step 4 Securely attach the thin twin BLACK cable to the negative terminal post of the Auxiliary battery Step 5 Securely attach the RED cable to the positive terminal post of the...

Page 5: ...5 5 WIRING GUIDE AUXILIARY DUAL BATTERY LOAD E g WATER PUMP LOAD E g FRIDGE VEHICLE STARTER BATTERY DC DC CHARGER LOAD E g LIGHTS YELLOW GREEN RED THIN BLACK OUTPUT BATTERY MONITOR...

Page 6: ...to OFF mode Press and hold the MODE button To set to AUTO mode Press and hold the MODE button The Battery Monitor is now set in the AUTO mode it will monitor the voltage and current and automatically...

Page 7: ...ng the Auxiliary battery This image shows that the Auxiliary battery is 12 8V and 2A current is being discharged from the Auxiliary battery By pressing the MODE button once the numeric Voltage value c...

Page 8: ...ad Factory default setting 11 8V Press the NEXT button to select your preferred value between 10 5 V 12 5V Then press the ENTER button to save Recovery Voltage This is the Voltage that the Battery Mon...

Page 9: ...and over Current limit The automatic shut off of the output load will occur after the Voltage or Current limit is reached for this delayed period Factory default setting 30sec Press the NEXT button to...

Page 10: ...Ground wire from the Auxiliary Battery negative terminal for 5 seconds then re attach If normal operation does not recommence immediately then the internal electronics are permanently damaged and the...

Page 11: ...tor will automatically restore power to the output loads when the voltage recovers and reaches the pre set Recovery Voltage value UNDER VOLTAGE OVER VOLTAGE When the Battery Monitor reaches the upper...

Page 12: ...re is greater than a set threshold it will automatically shut off the output load to prevent damage to the electronics inside This could happen if the ambient is very high and the system is drawing hi...

Page 13: ...ailure does not amount to a major failure The benefits provided to you as the consumer by this warranty are in addition to other rights and remedies available to you under the law THE WARRANTY DOES NO...

Reviews: