background image

120W Monocrystalline Solar Blanket

USER MANUAL

PLEASE READ AND UNDERSTAND THIS MANUAL 

COMPLETELY BEFORE USING THIS PRODUCT.

AKSR-BK120W_02

V1.6

Summary of Contents for AKSR-BK120W-02

Page 1: ...120W Monocrystalline Solar Blanket USER MANUAL PLEASE READ AND UNDERSTAND THIS MANUAL COMPLETELY BEFORE USING THIS PRODUCT AKSR BK120W_02 V1 6 ...

Page 2: ...mounted in a well ventilated area as far as possible from any ignition sources Do NOT smoke or have a naked flame in the vicinity of the battery under charge Never tamper with or pull any component of the solar blanket regulator or wiring apart If you do so you will void the warranty Always store the solar blanket neatly in its bag protected from the weather and with good ventilation Ensure nothin...

Page 3: ...perating Cell Temp NOCT 47 2 C Maximum System Voltage 1000VDC Maximum Series Fuse Rating 10A Operating Temperature 40 C to 85 C Application Class Class A PWM CONTROLLER SPECIFICATIONS Max Solar Input 50V Float Charge 13 7V Default Adjustable Discharge Stop 10 7V Default Adjustable Discharge Reconnect 12 6V Default Adjustable USB Output 5V 3A Dimensions 50 x 78 x 35 mm Weight 150g ...

Page 4: ...ns may cause damage to the PWM controller Ensure that you attach the positive and negative wires to the appropriate terminals 1 Connect the battery to the PWM controller 2 Connect the solar blanket to the PWM controller 3 Optional Connect the load you want to provide power to excluding batteries 4 Reverse the order to uninstall The controller will now be receiving power and its settings can be alt...

Page 5: ...LOAT VOLTAGE Accept power from the solar blanket until the battery s voltage reaches the set value Default 13 7V DISCHARGE RECONNECT Connect to the load when the battery s voltage reaches the set value Default 12 6V DISCHARGE STOP Sever the connection to the load when the battery s voltage reaches the set value Default 10 7V WORK MODE Control when the battery supplies power to the load 24H constan...

Page 6: ...cted Load icon is off Battery is low Charge the battery Incorrect menu setting is selected Select a menu setting where the load is displayed Load icon flashes slowly Overload Reduce the load s power draw The PWM controller will not turn on Battery is insufficiently charged Charge the battery Battery has been connected improperly Check and if necessary alter the battery s connection to the PWM cont...

Page 7: ...ailure does not amount to a major failure The benefits provided to you as the consumer by this warranty are in addition to other rights and remedies available to you under the law THE WARRANTY DOES NOT COVER a Any damage resulting from improper use b c The cost of removing and reinstalling the product d Travel and or other expenses due to customer s remote location e Transport charges and damage i...

Reviews: