The SIM-BNC-OPTOC kit also includes a BNC
connector safety cover.
The SIM-BNC-OPTOC module is required for all
Series configurations and should be used in con
-
junction with the DB9M CABLE (see below).
DB9M CABLE
– The DB9M (OPTOC) CABLE is a
high-voltage Interlock cable that provides superior
insulation for multi-amp series systems running
high-voltage applications.
The DB9M CABLE is required for all Series con
-
figurations and should be used in conjunction with
the SIM-BNC-OPTOC module (see above)
BAL RES KIT
– Three types available: 2105 BAL
RES KIT, 2110 BAL RES KIT and 2120 BAL RES
KIT. Ballast resistors are required for all Parallel
configurations. The ballast resistor kits include one
ballast resistor (two in the 2120 kit) with connec
-
tion terminals and mounting hardware. The 2105
BAL RES KIT also contains the shunt required to
defeat the amplifier’s external level control.
PARALLEL WIRING KITS
– Six types available:
2105 2-AMP, 2110/2120 2-AMP, 2105 3-AMP,
2110/2120 3-AMP, 2105 4-AMP, and 2110/2120
4-AMP. Parallel wiring kits include the DB-25
Interlock cable for system communication, BNC
T-connectors and BNC patch cables for wiring
parallel inputs through the BNC input connectors,
and the output wiring for connecting system ampli
-
fiers to the load. The kits also include the wire(s)
needed for wiring the parallel inputs through the
Removable Barrier Block (WECO) connectors and
the input terminators required during system setup.
Parallel wiring kits are recommended for all Paral
-
lel configurations.
To download the AE Techron
Multi-Amp Configu
-
ration Guide
or for additional information, visit the
AE Techron website at
www.aetechron.com.
6.3.1 Accessory Recommendations by System Type
Series Systems
2105, Two in Series:
(2) SIM-BNC-OPTOC input cards,
(1) DB9M OPTOC cable
2105, Three in Series:
(3) SIM-BNC-OPTOC input cards,
(2) DB9M OPTOC cables
6.3.2 Multi-Amp System Output
Capabilities (see following
pages)
Note: Performance levels typical up to 20 kHz fre
-
quency levels. Above 20 kHz, slew rate may affect
performance, reducing maximum voltage, current
and power output.
*Indicates no testing performed.
Parallel Systems
2105 Two in Parallel:
(2) 2105 BAL RES kits,
(1) 21050 2-AMP Parallel Wiring kit
2105 Three in Parallel:
(3) 2105 BAL RES kits,
(1) 2105 3-AMP Parallel Wiring kit
2105 Four in Parallel:
(4) 2105 BAL RES kits,
(1) 2105 4-AMP Parallel Wiring kit