Installation 2-12
2.4.4 Connecting Power
The
LVC 608/623/2016
uses a 3-wire (grounded) AC line system. At times, the
third wire ground may introduce a ground loop into the system.
Each
LVC 608/623/2016
is supplied from the factory with an appropriate AC
cord.
NOTE: Units destined for other parts of the world are provided without a
plug.
Whenever possible, connect the power cord to an isolated power circuit with
adequate current (see Section 3
Applications
for detailed information on current
draw).
Excessive line voltages of more than 11% above the amplifier's rated line voltage
will activate the overvoltage protection circuitry. For example, do not exceed a
line voltage of 133V AC for units set up for 120V AC operation.
All specifications in this manual were measured using 120V AC, 60 Hz power
mains unless otherwise noted. Specifications are derived using a peak main
voltage equal to the true peak of a 120V RMS sine wave with all available
channels fully loaded. Performance variations can occur at other AC main
voltages and line frequencies. In addition, line regulation problems will directly
affect the output power available from the amplifier.
A qualified technician can set up your amplifier for different AC main voltages
and frequencies by changing the power supply connections on the control board
inside the amplifier. The proper procedures are outlined inside the top cover of the
amplifier and in this manual in Section 3
Applications
.