Warranty, Maintenance, and Troubleshooting Guides
Limited Warranty
AEA Technology, Inc., warrants to the original purchaser that the Bravo MRI-3000 Analyzer shall be free
from defects in material or workmanship for a period of two (2) years from the date of shipment. All units
returned to the factory, delivery charges prepaid, and deemed defective under this warranty, will be
replaced or repaired at the company’s option. No other warranties are implied, nor will responsibility for
operation of this instrument be assumed by AEA Technology, Inc. There are no warranties that extend
beyond express warranties stated herein. No other warranties are expressed or implied. AEA
TECHNOLOGY SPECIFICALLY DISCLAIMS ALL IMPLIED WARRANTIES, INCLUDING THE IMPLIED
WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE. THE
REMEDIES PROVIDED HEREIN ARE
BUYER’S SOLE AND EXCLUSIVE REMEDIES. AEA
TECHNOLOGY, INC. SHALL NOT BE LIABLE FOR ANY DIRECT, INDIRECT, SPECIAL,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES, WHETHER BASED ON CONTRACT, TORT, OR
ANY OTHER LEGAL THEORY.
Remedies for any breach of warranty, either expressed or implied, are limited to repair, replacement,
or return of the instrument, at the option of AEA Technology, Inc. Any warranty is valid for the original
purchaser only.
All warranties of performance are disclaimed.
AEA Technology assumes no liability for applications assistance or customer product design.
Maintenance
There are NO field serviceable components inside the instrument. Do not attempt to open the
instrument, other than the battery compartment, as this can void the warranty. If the instrument is not
performing or charging correctly refer to Troubleshooting Guides at the end of this section or contact
AEA Technology, Inc. to communicate with a technical representative Monday-Friday 8:00am to
4:00pm Pacific Time.
Tel: US and Canada 1-800-258-7805, Interna1-760-931-8979
Fax: +1-760-931-8969
Email: techsupport@aeatechnology.com
Web: www.aeatechnology.com Be sure to include your email address and phone number and a
technical support staff member will respond the same day or next working day.
Battery Replacement Instructions
Preliminary: First ensure you have replacement cells on-hand. You will need 8 AA batteries of any
type, provided they are all of the same type and voltage. If you are using rechargeable batteries,
ensure they have sufficient charge. CAUTION: Mixing of cell types is highly inadvisable, and can lead
to faulty operation. Only use cells that are all of the same type and voltage.
Steps:
1. Remove the Belt Case, turn the MRI-3000 Analyzer OFF and remove any external power and/or
antenna or other DUT and place the Analyzer face down on a clean padded surface.
2. Lift the tilt stand to reveal the two battery cover screws and use a number 1 Philips
screwdriver to remove them.
3. Lift the battery cover and stand to expose the cells. DO NOT REMOVE the RETAINING
BAND across the upper four cells.
4. Remove the lower cells and slide the upper cells under the retaining band down to a vacant
location to remove them. If the cells are being replaced due to end-of-life cycle, please consult
your local regulations concerning hazardous waste disposal. DO NOT PLACE NIMH CELLS IN
THE TRASH.