background image

6

Description of the Hob

INSTALLATION

Any gas installation must be carried out by a registered CORGI installer, and in

accordance with existing rules and regulations.

The relevant instructions are to be found in the second section of this manual.
Please, ensure that, once the hob is installed, it is easily accessible for the engineer

in the event of a breakdown.

These instructions are only valid for countries whose identification symbols are shown on

the inside cover of this instruction booklet and on the appliance itself.

7

8

9

10

1

2

3

5

3

4

6

1. Hob Top
2. Rapid Burner
3. Semi-rapid Burners
4. Triple crown Burner
5. Auxiliary Burner
6. Control knob for back left burner (semi-rapid)
7. Control knob for back right burner (semi-rapid)
8. Control knob for front right burner (auxiliary)
9. Control knob for central burner (triple-crown)
10. Control knob for front left burner (rapid)

Summary of Contents for 34942 G

Page 1: ...34942 G Instruction Booklet Gas Hob GB...

Page 2: ...2...

Page 3: ...prevents them from using the appliance safely without supervision or instruction by a responsible persontoensurethattheycanusetheappliancesafely Thehobgetshotwhenitisinuse Childrenshouldbekeptawayunt...

Page 4: ...ofanoldappliance makeitunusable bycuttingoffthecable Thesymbol ontheproductoronitspackagingindicatesthatthisproductmay notbetreatedashouseholdwaste Insteaditshallbehandedovertotheapplicable collection...

Page 5: ...er 16 Buildingoverakitchenunitwithdoor 17 Fittingthehobtotheworktop 18 Electricalconnections 19 PermanentConnection 20 Wiringdiagram 20 FaultFinding 21 Preliminary Electrical Systems Check 21 Ignition...

Page 6: ...the event of a breakdown These instructions are only valid for countries whose identification symbols are shown on the inside cover of this instruction booklet and on the appliance itself 7 8 9 10 1...

Page 7: ...he spark generator to be activated automatically In the absence of electricity ignition can occur without the electrical device in this case approach the burner with a flame push the relevant knob dow...

Page 8: ...ports as shown in the diagram Assoonasaliquidstartsboiling turndowntheflamesothatitwillbarelykeeptheliquid simmering If you use a saucepan which is smaller than the recommended size the flame will spr...

Page 9: ...pbecomeheavilysoiled thefollowingproductsarerecommended Forstainlesssteelhobsuseaproprietarystainlesssteelcleaner For other hobs use Hob Brite or Bar Keepers Friend Pan Supports Thepansupportsaredishw...

Page 10: ...blown Check the burner cap and crown have been replaced correctly e g after cleaning Check the main jet is not blocked and the burner crown is clear of food particles Check the burner cap and crown ha...

Page 11: ...a 3 amp cartridge fuse HEAT INPUT Rear Left Burner 2 0 kW 6824 BTU HR semi rapid Front Left Burner 3 0 kW Natural Gas 10236 BTU HR rapid 2 8 kW L P G 9554 BTU HR Rear Right Burner 2 0 kW 6824 BTU HR...

Page 12: ...W 3 0 0 75 2 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE m3 h 0 286 0 057 0 190 0 038 0 095 0 028 0 381 0 114 NOZZLE REFERENCE 119 Adjust 96 Adjust 70 Adjust 146 Adjust 1 100 mm NOMINAL THERMAL POWER kW...

Page 13: ...alledinabedsitting roomwithavolumeoflessthan 20m3 If it is installed in a room of volume less than 5 m3 an air vent of effective area of 100 cm2 is required Ifitisinstalledinaroomofvolumebetween5m3 an...

Page 14: ...Ensurethatthereisaminimumdistanceof55 mm between the rear cut out edge and the wall A minimum distance of 150 mm must be left betweenthesideedgesofthecutoutandany adjacentcabinetsorwalls The minimum d...

Page 15: ...the shoulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with eit...

Page 16: ...or drawer it will be necessary to fit a heat resistant board below the base of the hob on the underside of the work surface It is also recommended to carry out the electrical connection to the hob as...

Page 17: ...tactwiththebottomofthehobwhich can be heated when it is operated The recommended solution is shown in diagram 3 The panel fitted under the hob a should be easily removable to allow easy access if tech...

Page 18: ...releftinthisseal in order to prevent spillage near the hob seepingintothecabinetbelow 1 Place the sealing gasket all around the edge of the cut out 2 Placethehobintothecutout and secure it by means of...

Page 19: ...nge the fuse a 3ampASTAapproved BS 1362 fuse must be used Should the plug need to be replaced for any reason the wires in the mains lead are coloured in accordance with the following code Green and Ye...

Page 20: ...3 mm between the switch contacts and of a type suitable for the required load in compliance with the current electric regulations The switch must not break the yellow and green earth cable at any poin...

Page 21: ...supply should now be satisfactory Carry out D Resistance to Earth check Inlet wiring faulty Rectify any fault Isolate appliance and carry out B Insulation check Rectify any fault including replacing f...

Page 22: ...t leads from L to N in appliance terminal block If meter reads 0 then there is a short circuit b meter set on W Ohm x 100 scale Repeat test with leads from L to E If meter reads less than infinity the...

Page 23: ...he electrode Check by pass simmer adjusted Light burner manually Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and...

Page 24: ...ap see diagram The b type has the adjustment screw located down the centre of th egas tap control shaft The c type has the by pass screw located to the side of the gas tap itself To adjust use a thin...

Page 25: ...tysupply 3 Remove all pan supports burner caps rings crowns and control knobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewed and replaced by the appropriate LPG injecto...

Page 26: ...rviced maintained repaired takenapartortamperedwith by any person not authorised by us Electrolux Service Force Centre must undertake all service work under this guarantee Anyapplianceordefectivepartr...

Page 27: ...t of your appliance requiring service or if you wish to purchase spare parts please contactyourlocalServiceForceCentrebytelephoning 08705929929 YourtelephonecallwillbeautomaticallyroutedtotheServiceFo...

Page 28: ...eappliance guaranteewillmovewithyousubjecttothefollowingqualificati ons Theapplianceguaranteestartsfromthedateyoufirstpurchasedtheappliance whichwillbeevidencedbyproductionofavalidpurchasedocumentissu...

Page 29: ...29...

Page 30: ...30...

Page 31: ...31...

Page 32: ...35690 3002 12 07 R 0 Subject to change without notice...

Reviews: