10
Slide the hole cover out of the
ventilation grille by pushing it
in the direction of the arrow
and reassemble it on the oppo-
site side;
10. refit the ventilation grille, fix-
ing the screws;
11. reassemble the lower door;
12.reassemble the middle hinge
on the opposite side;
13.replace the upper door.
14.In your documentation bag
you will find the upper hinge
necessary to make the
reversibility. Please mount it in
their relevant place.
15)Unscrew the top handle bracket
from the handle rod (1). Unscrew
the bottom handle bracket from
the door (2).
Unscrew the top handle bracket
from the door (3) and screw onto
the bottom right-hand side of
the door (4).
Turn the handle bracket with the
handle rod 180° and screw them
to the door (5) and the fitted
handle bracket (6).
Move the small plug from right to
left. Reposition, level the
appliance, wait for at least one
hour and then connect it to the
mains socket.
In any case you do not want to carry out the above mentioned operations, con-
tact the nearest Service Force Centre. The Service Force specialist will carry
out the reversibility of the doors at your cost.
Attention:
After having reversed the opening direction of the doors check that
all the screws are properly tightened and that the magnetic seal adheres to the
cabinet. If the ambient temperature is cold (i.e. in Winter), the gasket may not
fit perfectly to the cabinet. in that case, wait for the natural fitting of the gas-
ket or accelerate this process by heating up the part involved with a normal
hairdryer.