background image

11

Overall dimensions

Width:

580 mm.

Depth:

500 mm.

Cut out dimensions

Width:

550 mm.

Depth:

470 mm.

Supply Connections

Gas:

RC 1/2 inch (1/2 inch male) Rear right

hand corner

Electric:

230-240V 50Hz supply, 3 core flexible

cable with non rewireable plug fitted with a 3 amp

cartridge fuse.

Ignition HT Spark

Spark Generator:

Ispra Control's BF 50046 -

230-240V  0.6 YA  T120

Spark Gap

 : Fixed

Instructions for the Installer

Engineers technical data

Heat Input

Rear Left Burner

2.0 kW (6824 BTU/HR)

(semi rapid)

Front Left Burner

3.0 kW Natural Gas

(rapid)

(10236 BTU/HR)

2.8 kW L.P.G.

 (9554 BTU/HR)

Rear Right Burner 2.0 kW  (6824 BTU/HR)

(semi rapid)

Front Right Burner 1.0 kW (3412 BTU/HR)

(auxiliary)

Appliance class

3

Appliance category

II2H3+

Gas supply

Natural gas G20 / 20mbar

BURNER

RAPID

SEMI-RAPID

AUXILIARY

(large)

(medium)

(small)

POSITION

MAX

MIN

MAX

MIN

MAX

MIN

  NOMINAL  THERMAL

 POWER        kW

3.0

0.65

2.0

0.45

1.0

0.33

  NOMINAL  FLOW

 RATE           m

3

/h

0.286

0.057

0.190

0.038

0.095

0.028

  NOZZLE  REFERENCE

119

Adjust.

96

Adjust.

70

Adjust.

1/100  mm

  NOMINAL  THERMAL

 POWER        kW

2.8

0.65

2.0

0.45

1.0

0.33

  NOMINAL  FLOW

 RATE           g/h

202

43.5

144

29

72

21,5

  NOZZLE  REFERENCE

86

40

71

32

50

28

1/100  mm

NATURAL  GAS

20  mbar

VALUE  =

37.78  MJ/m

3

Ws  -  50.7  MJ/  m

3

TYPE OF GAS

LPG  GAS

28-30/37  mbar

VALUE  =

49.92  MJ/Kg

All manuals and user guides at all-guides.com

all-guides.com

Summary of Contents for 21601C

Page 1: ...Table de cuisson Gaskookplaat Piano di cottura Operating and Installation Instructions Notice d utilisation et d encastrement Gebruiksaanwijzing en Installatievoorschrift Istruzioni per l uso e l installazione GB NL IT FR All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 2: ...ontherating plate locatednearthegassupplypipe l Donotattempttomodifythehobinanyway Child Safety l Thishobisdesignedtobeoperatedbyadults Donotallowchildrentoplaynearor withthehob l Thehobgetshotwhenitisinuse Childrenshouldbekeptawayuntilithascooled l Childrencanalsoinjurethemselvesbypullingpansorpotsoffthehob During Use l Thishobisintendedfordomesticcookingonly Itisnotdesignedforcommercialor indust...

Page 3: ...s l Neveruseplasticoraluminiumfoildishesonthehob l Perishablefood plasticitemsandareosolsmaybeaffectedbyheatandshouldnot bestoredaboveorbelowthehobunit Service l This hob should only be repaired or serviced by an authorised Service Engineer andonlygenuineapprovedsparepartsshouldbeused Environmental Information l Afterinstallation pleasedisposeofthepackagingwithdueregardtosafetyandthe environment l...

Page 4: ...lInformation Contents F Instructions for the User Important Safety Information 2 Guide to Use the instructions 4 Description of the Hob 5 Operation 6 Maintenance and Cleaning 7 Something Not Working 8 Service and Spare Parts 9 Customer Care 9 Guarantee Conditions 10 Instructions for the Installer Important safety requirements 12 Installation 13 Building In 15 Electrical connections 18 Wiring diagr...

Page 5: ...installation must be carried out by a registered CORGI installer and in accordance with existing rules and regulations Therelevantinstructionsaretobefoundinthesecondsectionofthismanual Please ensurethat oncethehobisinstalled itiseasilyaccessiblefortheengineerinthe eventofabreakdown WHEN THE HOB IS FIRST INSTALLED Oncethehobhasbeeninstalled itisimportanttoremoveanyprotectivematerials which wereputo...

Page 6: ...nimum maximum diameter diameter Large rapid 180 mm 260 mm Medium semi rapid 120 mm 220 mm Small Auxiliary 80 mm 160 mm Operation Assoonasaliquidstartsboiling turndowntheflame sothatitwillbarelykeeptheliquidsimmering If you use a saucepan which is smaller than the recommended size the flame will spread beyond the bottom of the vessel causing the handle to overheat Take care when frying food in hot ...

Page 7: ...ob top become heavily soiled it is recommended that a cleaning product such as Hob Brite or Bar Keepers Friend is used Pan Supports Thepansupportsaredishwasherproof Ifwashingthembyhand takecarewhendrying themastheenamellingprocessoccasionallyleavesroughedges Ifnecessary remove stubbornstainsusingapastecleaner The Burners The burner caps and crowns can be removed for cleaning Wash the burner caps a...

Page 8: ...ownhave beenreplacedcorrectly e g after cleaning u Checkthemainjetisnotblockedandthe burnercrownisclearoffoodparticles u Checktheburnercapandcrownhave beenreplacedcorrectly e g after cleaning Ifafterallthesechecks yourhobstilldoesnotoperatecorrectly contactyourlocalService ForceCentre Please note that it will be necessary to provide proof of purchase for any in guarantee service calls In guarantee...

Page 9: ...If you require spare parts or an engineer contact your local Service Force Centre by telephoning 0870 5 929 929 YourcallwillberoutedtotheyourlocalServiceForceCentre For general enquiries concerning yourAEG appliance and for further information on AEGproducts contactourCustomerCareDepartmentbyletterortelephoneasfollows CustomerCareDepartment AEGDomesticAppliances 55 77HighStreet Slough Berkshire SL...

Page 10: ...eriodfortheappliance Partsremoved duringguaranteerepairsbecomepropertyofAEG 6 Thepurchaser sstatutoryrightsarenotaffectedbythisguarantee European Guarantee If you should move to another country within Europe then your guarantee moves with you to your new home subjecttothefollowingqualifications Theguaranteestartsfromthedateyoufirstpurchasedyourproduct Theguaranteeisforthesameperiodandtothesameexte...

Page 11: ...54 BTU HR RearRightBurner 2 0kW 6824BTU HR semi rapid FrontRightBurner 1 0 kW 3412 BTU HR auxiliary Applianceclass 3 Appliancecategory II2H3 Gassupply NaturalgasG20 20mbar BURNER RAPID SEMI RAPID AUXILIARY large medium small POSITION MAX MIN MAX MIN MAX MIN NOMINAL THERMAL POWER kW 3 0 0 65 2 0 0 45 1 0 0 33 NOMINAL FLOW RATE m3 h 0 286 0 057 0 190 0 038 0 095 0 028 NOZZLE REFERENCE 119 Adjust 96 ...

Page 12: ...airventisrequired evenifthevolumeisbetween5m3 and11m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition shouldbeconsultedtodeterminetherequisiteairventrequirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroomorshowerroom Beforemakingthecutoutintheworktopensurethatthereisaminimumdistanceof55 mm betwe...

Page 13: ...WITH A COOKER HOOD ABOVE FO 0813 FO 0812 Installation Important This hob must be installed by qualified personnelto the relevant British Standards Any gas installation must be carried out by a CORGI registered installer The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this book be ignored 700 mm All manuals and user gu...

Page 14: ... of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper TheconnectionshouldbesuitableforconnectingtoR1 2 1 2BSPmalethread When the final connection has been made it is essential that a thorough leak test is carriedoutonthehobandins...

Page 15: ...er a cupboard or drawer Ifthehobistobeinstalledaboveacupboardordraweritwillbenecessarytofitaheat resistantboardbelowthebaseofthehobontheundersideoftheworksurface It is also recommended to carry out the electrical connection to the hob as shown in diagrams1and2 Seenextpage All manuals and user guides at all guides com ...

Page 16: ...ycontactwiththebottomofthehobwhich can be heated when it is operated The recommendedsolutionisshownindiagram 3 Thepanelfittedunderthehob a should beeasilyremovabletoalloweasyaccess iftechnicalassistanceisneeded Thespace behind the kitchen unit b can be used forconnections 30 20 min 60 a b FO 1013 3 Dimensions are given in mm All manuals and user guides at all guides com a l l g u i d e s c o m ...

Page 17: ...ealinordertoprevent spillagenearthehobseepingintothecabinetbelow 1 Placethesealinggasketallaroundtheedgeofthecutout 2 Placethehobintothecutoutandsecureitbymeansoftherelevantfixingclampsand screws as shown in the diagram 3 Remove the excess seal Theedgeofthehobformsadoublesealwhichpreventstheingressofliquids F FO 0199 a Seal All manuals and user guides at all guides com ...

Page 18: ...ould the plug need to be replaced for any reason the wires in the mains lead are colouredinaccordancewiththefollowingcode GreenandYellow Earth Blue Neutral Brown Live 1 Connect the green and yellow earth wire to the terminal in the plug which is marked withtheletter E ortheearthsymbol or colouredgreenandyellow 2 Connecttheblue neutral wiretotheterminal intheplugwhichismarkedwiththeletter N orcolou...

Page 19: ...ycorddoesnotcomeintocontactwithsurfaceswithtemperatures higherthan50deg C Wiring diagram 1 TAPS IGNITOR SWITCHES 2 IGNITOR UNIT 1 2 L N 0 220 240 1 2 3 4 Replacement of the cable Theconnectionofthevoltagecabletotheappliance sterminalblockisoftype Y This meansthatitsreplacementrequiresthespecificequipmentofatechnician Inthiscase onlycabletypesH05RR F H05V2V2 F T90 orH05BB Fmustbeused Thecablesectio...

Page 20: ...e satisfactory Carry out D Resistance to Earth check Inlet wiring faulty Rectify any fault Isolateapplianceand carry out B Insulation check Rectify any fault includingreplacing fuses as necessary NO YES SOCKET face view PLUG with cover removed Earth Wire Green Yellow Neutral Wire Blue FUSE E N L Brown Blue Green Yellow Green Yellow Brown Blue NO YES All manuals and user guides at all guides com ...

Page 21: ...toNinapplianceterminalblock Ifmeterreads 0 thenthereisa shortcircuit b meter set on W Ohm x 100 scale RepeattestwithleadsfromLtoE Ifmeterreadslessthan infinity thereisafault NOTE Shoulditbefoundthatthefusehasfailedbutnofaultisindicated adetailedcontinuity check i e by disconnecting and checking each component is required to trace the faulty component Itispossiblethatafaultcouldoccurasaresultofloca...

Page 22: ...simmer adjusted Lightburnermanually Check continuity from N on the mains connector block and O on theignitorunit Check continuity from L on the mainsconnectorblockandthe tapsignitionswitches Checkcontinuityfromignition switchesconnectortoignitorunit Check continuity from the tip of eachelectrodetotheterminals1 to4ontheignitorunit Check for breaks in the insulation of the HT leads NO Changetheignit...

Page 23: ...settoMIN 2 Removethecontrolknob 3 To adjust use a thin bladed screwdriverandturntheadjustment screwuntiltheflameissteadyand doesnotextinguish whentheknob isturnedfromMINtoMAX Repeat thisprocedureforallburners Pressure Testing 1 Removelefthandpansupportandfrontleftburnercapandcrown 2 Fitmanometertubeovertheinjector 3 Turnontheburnergassupplyandigniteanotherburnersupply Thepressurereadingshouldbenom...

Page 24: ...fromtheelectricitysupply 3 Removeallpansupports burnercaps rings crownsandcontrolknobs 4 Withtheaidofa7mmboxspannertheburnerinjectorscanthenbeunscrewedand replacedbytheappropriateLPGinjectors To adjust the gas rate Withtheaidofathinbladedscrewdrivercompletelytightendownthebypassadjustment screw Uponcompletionstickthereplacementratingplateontheundersideofthehob IMPORTANT Thereplacement conversionof...

Reviews: