19
Installation
INSTALLATION
7.
Safety
Only a qualified contractor should carry out installation,
commissioning, maintenance and repair of the appliance.
7.1
General safety instructions
We guarantee trouble-free function and operational relia-
bility only if original accessories and spare parts intended
for the appliance are used.
!
Material losses
Observe the maximum inlet temperature.
Higher
temperatures may damage the appliance.
You can
limit the maximum inlet temperature by installing a
central thermostatic valve.
7.2
Instructions, standards and regulations
Note
Observe all applicable national and regional regula
-
tions and instructions.
◦
The protection rating IP 25 (hoseproof) can only be
ensured with a correctly fitted cable grommet.
◦ The specific electrical resistance of the water must
not fall below that stated on the type plate. In a linked
water network, observe the lowest electrical water
resistance (see chapter «Specification / Application
areas / Conversion table»). Your water supply utility
will advise you of the specific electrical water resist
-
ance or conductivity.
8.
Appliance description
8.1
Standard delivery
The following are delivered with the appliance:
◦
Wall mounting bracket
◦
Threaded stud for wall mounting
◦
Installation template
◦
2 twin connectors (cold water with shut-off valve)
◦
Flat gaskets
◦
Cable grommet (power cable from above / below)
◦
Screws / rawl plugs for additional securing of the
back panel when making water connections on fin
-
ished walls
9.
Preparations
9.1
Installation site
!
Material losses
Install the appliance in a room free from the risk of
frost.
» Always install the appliance vertically and near the
draw-off point.
The appliance is suitable for undersink and oversink in-
stallations.
Undersink installation
26
_0
2_0
2_
13
45
1
2
1 Cold water inlet
2 DHW outlet
Oversink installation
1
2
26
_0
2_0
2_
13
44
1 Cold water inlet
2 DHW outlet
Note
»
Mount the appliance on the wall.
The wall must
have a sufficient load-bearing capacity.
9.2
Minimum clearances
≥50
≥50
≥90
≥90
D
00000
60
80
9
» Maintain the minimum clearances to enable mainte-
nance work on the appliance.
9.3
Water installation
◦
Never operate with preheated water.
◦
A safety valve is not required.
◦
Safety valves are not permissible in the DHW pipe.
» Flush the water line thoroughly.
»
Ensure that the flow rate for switching on the appli
-
ance is achieved (see chapter «Specification / Data
table», On). Increase the mains water pressure if the
required flow rate is not achieved with the draw-off
valve fully opened.