background image

75

of the same size as the ventilation hole”, a hole of 500-600 cm

2

,

which is to say a larger hole, could reduce the performance of the
extractor hood.

• If the hood is used in its filtering function, it will operate simply and

safely in the above conditions without the need for any of the
aforementioned measures.

• When the hood is used in its extractor function, the following rules

must be followed to obtain optimal operation:
— short and straight outlet hose
— keep bends in outlet hose to a minimum
— never install the hoses with an acute angle, they must
    always follow a gentle curve
— keep the hose as large as possible (120 mm Ø min.).

• Failure to observe these basic rules will drastically reduce the

performance and increase the noise levels of the extractor hood.

Summary of Contents for 240 D

Page 1: ...240 D Dunstabzugshaube Hotte aspirante Afzuigkap Cooker Hood Montage und Gebrauchsanweisung Manuel de montage et d utilisation Installatie en gebruksaanwijzing Operating and Installation Instructions ...

Page 2: ...68 Printed on recycled paper AEG putting words into action ...

Page 3: ...peed 78 Hood lighting 78 Intensive speed P 78 Fan timer 79 Switching off the fan 79 Hood operation before and after cooking 80 Warnings on the activated carbon filter 80 Display warning on saturation of activated carbon filter 81 Open the metal grease filter 82 Display warning on saturation of metal grease filter 83 Safety Warnings for user 85 Maintenance and care 86 Attention 86 Changing the ligh...

Page 4: ...located on the top of the unit while the other B is located on the rear To connect up the hose you should first fit the bayonet mounting flange C Ø 120 mm on the outlet required if using the top outlet fix the flange in place using the screw supplied as shown in Fig 1 Close off the unused hole using the bayonet fitting caps D Important To use the back hole B remove switch F from the top hole See F...

Page 5: ...tion see Special Accessories Summer Winter Hood Conversion To avoid excessive heat loss during the winter months we recommend that the hood be converted from extractor version to filter version In order to convert the hood a activated carbon filter available as an accessory is required Follow the instructions for operating the hood to recirculate air When the temperature outdoors becomes more mild...

Page 6: ...If the appliance is permanently connected to the mains then it must be isolated from the mains using measures provided in the electrical installation fuses unscrew type fuses cut out current trips or similar that have a contact separation of 3mm when open The manufacture declines all responsibility for malfunctions resulting from failure to comply with the above instructions If the power socket is...

Page 7: ...kg Maximum absorbed power 330 W Motor absorption 2 x 125 W Lighting 2 x 40 W Length of the cable 110 cm Fan powers speed speed in compliance with DIN 44971 Extractor version Speed min 131 m3 h max 251 m3 h intensive 360 m3 h Filter version Speed min 50 m3 h max 125 m3 h intensive 140 m3 h Flange 120 mm Ø ...

Page 8: ...pply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities When the unit is used in its extractor version a sufficiently large ventilation hole must be provided with dimensions that are approximately the same as the outle...

Page 9: ...y of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet hose to a minimum never install the hoses with an acute angle they must always follow a gentle curve keep the hose as large as possible 120 mm Ø min Failure to observe these basic rules will drastically...

Page 10: ...nce Fig 4 Wall mounting Fix the drilling template to the wall Make 3 Ø 8mm holes in the wall 2 at points I 1 as desired at points L Insert the three Ø 8mm expansion plugs into the wall Insert two 5x45 screws at points I but do not tighten them completely Adjust the unit so that it is positioned at a right angle to the wall by turning the two support screws G Fit the hood into holes I tighten the 2...

Page 11: ... activated carbon filters C Decrease fan speed button for reducing speed of motor from high speed P down to speed 1 Increase fan speed button for increasing speed of motor from 1 to 9 and high speed P If the hood fails to operate correctly briefly disconnect it from the mains power supply for almost 5 sec by pulling out the plug Then plug it in again and try once more before contacting the Technic...

Page 12: ...want press the decrease speed button E until the correct speed is shown on the display D Hood lighting Simply press the button A to switch the lighting on or off Intensive speed P To select the intensive speed P press the increase speed button F until the letter P high speed is shown on the display D Press the button E to slow down from intensive speed operation The speeds 9 1 will once again be s...

Page 13: ...switch on the fan timer It will automatically switch off after 15 minutes operation at the selected speed A red dot will flash on and off on the display D Switching off the fan Press the key B to switch off the fan at any speed including P After 5 seconds the number 0 Fig 9 will be shown on the display D followed finally by only the red dot Fig 10 min min 9 10 B D D ...

Page 14: ...d The effective elimination of cooking odours depends on the functional adaptation of the volume of activated carbon to the hood s air flow and a carefully determined position of the filter inside the hood This combination inevitably decreases the air flow compared to the extractor version A decisive parameter for the elimination of cooking odours is what is known as the residence time of the air ...

Page 15: ...ed This operation should be carried out every 120 operating hours Warning The metal grease filters must be cleaned when you change the activated carbon filter Proceed as follows to remove and change the activated carbon filter Switch of the fan motor by pressing the button Take the precaution of removing the cartridge fuses from their fuse holders or tripping the automatic circuit breaker to ensur...

Page 16: ...ivated carbon filter cannot be cleaned or reused Clean the inner housing using a hot detergent solution only never use caustic detergents abrasive powders or brushes Dismounting Unhook the carbon filter from its housing pushing hooks C Always specify the hood model code number and serial number when ordering replacement filters This information is shown on the registration plate located on the ins...

Page 17: ...ady for use again Display warning on saturation of metal grease filter After 30 operating hours the letter F grease filters will flash on and off on the display D in alternation with the fan speed setting This means that the metal grease filters need to be cleaned This operation should be carried out every 30 operating hours Proceed as follows to remove and clean the metal filters Switch of the fa...

Page 18: ... filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process When washing the metal grease filter in the dishwasher a slight discoloration of the filter can occur Wait until the filters are completely dry then replace them in their original positions taking care that there are no gaps between the two filters Screw the fuses back in or rese...

Page 19: ...n the oil being used is dirty It is extremely important to note that overheating can cause a fire Never carry out any flambé cooking under the hood Always disconnect the unit from the power supply before carrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very important to clean the ho...

Page 20: ... light does not come on make sure the bulb has been screwed in correctly before contacting the technical assistance service Cleaning Warning always disconnect the hood from the mains power supply before cleaning it Never insert pointed objects in the motor s protective grid Wash the outside surfaces using a delicate detergent solution Never use caustic detergents or abrasive brushes or powders Onl...

Page 21: ... technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be ready to specify 1 The model code number 2 The serial number E Nr 3 The manufacturing number F Nr This information is shown on the registration plate inside the unit behind the grease filter We reserve the right to change specifications and colours as a result of our policy of con...

Page 22: ...AEG Hausgeräte AG Postfach 1036 D 90327 Nürnberg Copyright by AEG H 259 246 000 LI1CWB Ed 06 01 ...