12
9
If the hob is not working correctly, please carry out the following checks before
contacting your local AEG Service Force Centre.
Something Not Working
SYMPTOM
• There is no spark when lighting
the gas
• The gas ring burns unevenly
SOLUTION
• Check that the unit is plugged in
and the electrical supply is
switched on
• Check that the RCCB has not
tripped (if fitted)
• Check the mains fuse has not
blown
• Check the burner cap and crown
have been replaced correctly, e.g.
after cleaning.
• Check the main jet is not blocked
and the burner crown is clear of
food particles.
• Check the burner cap and crown
have been replaced correctly, e.g.
after cleaning.
If after all these checks, your hob still does not operate correctly, contact your local
AEG Service Force Centre.
Please note that it will be necessary to provide proof of purchase for any in-guarantee
service calls.
In-guarantee customers should ensure that the above check have been made as the
engineer will make a charge if the fault is not a mechanical or electrical breakdown.
Technical Data
Burner
Ø Tap By-Pass 1/100 mm
Small auxiliary
27
Medium semi-rapid
29
Large rapid
39
Standard
65
By-pass diameters
Dimensions in mm:
Hob H x W x D
90 x 680 x 510
Installation opening W x D
560 x 480
Burner power in kW:
Small auxiliary burner
1,00
Medium semi-rapid burner
1,65
Large rapid burner
3,0
Triple flame burner standard
4,25
Category
II 2H3+
Gas intake connection
G 1/2”
Gas pressure
G20 - 20 mbar
Electricity supply
230 V ~ 50 Hz
Appliance class
3
MAXIMUM
MINIMUM
G 20
G30/G31
BURNER
OUTPUT
OUTPUT
20 mbar
28-30/37 mbar
TYPE
(gcv)
kW
kW
Nozzle Nominal Nozzle Nominal
marking flow rate marking flow rate
100/mm
m
3
/h
100/mm
g/h
Small aux burner
1,00
0,30
76
0,095
50
73
Medium semi-rapid b.
1,65
0,32
94
0,157
65
120
Large rapid burner
3,00
0,65
128
0,286
85
219
T.F. burner std
4,25
1,50
63+140
0,405
37+97
310