12
Installation
Unpacking
Check that the cooker hood is not damaged. Transportation damages
should immediately be reported to the transport company. Damages, faults
and missing parts should immediately be reported to the retailer.
Dispose carefully of the packaging material so that it is out of the way of
small children.
Position
The cooker hood should be mounted freely hanging on the wall. The
cooker
hood must be at least 50 cm above electric hobs or electric ranges, or at
least 65 cm above gas burners or gas ranges.
The cooker hood cannot be connected to flues of other
appliances that run on energy sources other than electricity.
Please, keep to the provisions of official directives regarding fume
discharge.
Electrical connection
The electric outlet should be placed inside the chimney.The hood has a
power cable, 100 cm, with earth connection and the rated voltage is
220 - 240 V.
Connect the hood to the mains supply via a double pole switch
which has 3 mm minimum clearance between the contacts 220-240 V.
The following is valid in the United Kingdom only:
As the colours of the wires in the mains lead of this appliance may not
correspond with the coloured markings identifying the terminals in your plug,
proceed as follows:
-
the wire which is coloured green and yellow must be connected to the
terminal in the plug which is marked with the letter E or by the earth
symbol (
), or coloured green or green and yellow;
-
the wire which is coloured blue must be connected to the terminal which
is marked with the letter N or coloured black, -
-
the wire which is coloured brown must be connected to the terminal
which is marked with the letter L or coloured red.