background image

18

ON/OFF SWITCH

FLEX
OUTLET

ON/OFF SWITCH

FLEX
OUTLET

FO 0763

FO 0764

1

2

Building over a kitchen unit with door

Proper arrangements must be

taken in designing the furniture

unit, in order to avoid any contact

with the bottom of the hob which

can be heated when it is operated.

The recommended solution is

shown in diagram 3.
The panel fitted under the hob

("a") should be easily removable

to allow easy access if technical

assistance is needed. The space

behind the kitchen unit ("b") can

be used for connections.

30

20 min

60

a

b

FO 1013

3

Dimensions are given in mm.

Building in

Summary of Contents for 34942G

Page 1: ...s de cuisson Gaskookplaten Piani di cottura PERFEKT IN FORM UND FUNKTION Operating and Installation Instructions Notice d utilisation et d encastrement Gebruiksaanwijzing en Installatievoorschrift Istruzioni per l uso e l installazione GB FR NL IT ...

Page 2: ...r Removeallpackagingbeforeusingthehob Ensurethatthegasandelectricalsupplycomplieswiththetypestatedon theratingplate locatednearthegassupplypipe Donotattempttomodifythehobinanyway ChildSafety Thishobisdesignedtobeoperatedbyadults Donotallowchildrento playnearorwiththehob Thehobgetshotwhenitisinuse Childrenshouldbekeptawayuntilithas cooled Childrencanalsoinjurethemselvesbypullingpansorpotsoffthehob ...

Page 3: ...useanaccidentbytippingorspillage Neverleavethehobunattendedwhencookingwithoilandfats Neveruseplasticoraluminiumfoildishesonthehob Perishablefood plasticitemsandareosolsmaybeaffectedbyheatand shouldnotbestoredaboveorbelowthehobunit Service ThishobshouldonlyberepairedorservicedbyanauthorisedService Engineerandonlygenuineapprovedsparepartsshouldbeused EnvironmentalInformation Afterinstallation please...

Page 4: ...gineerstechnicaldata 12 Importantsafetyrequirements 14 Location 14 Installation 15 GasConnection 16 CutOutSize 17 Building In 17 Buildingoveracupboardordrawer 17 Building over a kitchen unit with door 18 Fitting the hob to the worktop 19 Electricalconnections 20 PermanentConnection 21 Wiringdiagram 21 FaultFinding 22 PreliminaryElectricalSystemsCheck 22 IgnitionSystem GasIgnition 24 Commissioning ...

Page 5: ...ectives 73 23EEC 90 683EEC 93 68EEC 89 336EEC 90 396EEC current edition GuidetoUsetheinstructions The following symbols will be found in the text to guide you throughout the Instructions SafetyInstructions Step by step instructions for an operation HintsandTips ...

Page 6: ...er rapid Description of the Hob Mod 34942 G INSTALLATION AnygasinstallationmustbecarriedoutbyaregisteredCORGI installer and in accordance with existing rules and regulations The relevant instructions are to be found in the second section of this manual Please ensurethat oncethehobisinstalled itiseasilyaccessiblefor the engineer in the event of a breakdown WHENTHEHOBISFIRSTINSTALLED Oncethehobhasbe...

Page 7: ...eed before putting a pan on the pan support Tolightaburner turntherelevantknobanticlockwisetomaximumposition thenpushitdowntoignitetheburner Uponignition adjusttheflame asrequired If the burner does not ignite turn the control knob to zero and try again When switching on the mains after installation or a power cut it is quite normal for the spark generator to be activated automatically In the even...

Page 8: ...steelwoolpads bath sinkstainremovers Shouldthehobtopbecomeheavilysoiled itisrecommendedthata cleaningproductsuchasHobBriteorBarKeepersFriendisused PanSupports Whenwashingthepansupportsbyhand takecarewhendryingthem astheenamellingprocessoccasionallyleavesroughedges Ifnecessary removestubbornstainsusingapastecleaner TheBurners Theburnercapsandcrownscanberemovedforcleaning Washtheburnercapsandcrownsu...

Page 9: ...burnercapandcrown havebeenreplacedcorrectly e g aftercleaning Checkthemainjetisnotblocked and the burner crown is clear of foodparticles Checktheburnercapandcrown havebeenreplacedcorrectly e g aftercleaning If after all these checks your hob still does not operate correctly contact yourlocalAEGServiceForceCentre Please note that it will be necessary to provide proof of purchase for any in guarante...

Page 10: ...0 5 929 929 Your call will be routed to your local Service Force Centre For the address of your local Service Force Centre and further information about Service Force please visit the website at www serviceforce co uk CUSTOMER CARE For general enquiries concerning your AEG appliance and for further information on AEG products contact our Customer Care Department by letter or telephone at the addre...

Page 11: ...ovable parts of glass or plastic Costs incurred for calls to put right an appliance which is improperly installed or calls to appliances outside the United Kingdom Appliances found to be in use within a commercial environment plus those which are subject to rental agreements Products of AEG manufacture which are not marketed by AEG European Guarantee If you should move to another country within Eu...

Page 12: ... IGNITIONHTSPARK SparkGenerator IspraControl sBF50066 230 240V 0 6YA T120 SparkGap Fixed HEATINPUT Rear Left Burner semi rapid 2 0 kW 6824 BTU HR Front Left Burner rapid 3 0 kW Natural Gas 10236 BTU HR 2 8 kW L P G 9554 BTU HR Central Burner triple crown 4 0 kW 13652 BTU HR Rear Right Burner semi rapid 2 0 kW 6824 BTU HR Front Right Burner auxiliary 1 0 kW 3412 BTU HR APPLIANCECLASS 3 APPLIANCECA ...

Page 13: ... 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE m3 h 0 286 0 057 0 190 0 038 0 095 0 028 0 381 0 114 NOZZLE REFERENCE 119 Adjust 96 Adjust 70 Adjust 146 Adjust 1 100 mm NOMINALTHERMAL POWER kW 2 8 0 65 2 0 0 45 1 0 0 33 4 0 1 2 NOMINAL FLOW RATE g h 202 43 5 144 29 72 21 5 252 86 NOZZLEREFERENCE 86 40 71 32 50 28 98 56 1 100 mm NATURALGAS 20mbar VALUE 37 78MJ m3 Ws 50 7MJ m3 TYPEOFGAS LPGGAS 28 30 37mb...

Page 14: ... door which opens directly to the outside no air vent is required even if the volume is between 5 m3 and 11 m3 If there are other fuel burning appliances in the same room B S 5440 Part 2 Current Edition should be consulted to determine the requisite air vent requirements Location The hob may be located in a kitchen a kitchen diner or bed sitting room but not in a bathroom or shower room Before mak...

Page 15: ...lified personnel to the relevant British Standards Any gas installation must be carried out by a CORGI registered installer The manufacturer will not accept liability should the above instructions or any of the other safety instructions incorporated in this book be ignored 700 mm 420 mm 100 mm 420 mm 50 mm 50 mm 55 mm 650 mm 420 mm 420 mm 100 mm 50 mm 50 mm 55 mm FO 2027 FO 2028 700 mm Installatio...

Page 16: ...oulder on the end of the thread fitted to the hob connecting pipe Failure to ensure the correct assembly will cause leakage of gas Gas Connection Connection to the gas supply should be with either rigid or semi rigid pipe i e steel or copper The connection should be suitable for connecting to RC 1 2 1 2 BSP male thread When the final connection has been made it is essential that a thorough leak te...

Page 17: ...f the hob is to be installed above a cupboard or drawer it will be necessary to fit a heat resistant board below the base of the hob on theundersideoftheworksurface It is also recommended to carry out the electrical connection to the hobasshownindiagrams1and2 seenextpage Building in 830 470 55 min 860 500 FO2407 ...

Page 18: ...e unit in order to avoid any contact with the bottom of the hob which canbeheatedwhenitisoperated Therecommendedsolutionis shownindiagram3 The panel fitted under the hob a shouldbeeasilyremovable toalloweasyaccessiftechnical assistanceisneeded Thespace behind the kitchen unit b can beusedforconnections 30 20 min 60 a b FO1013 3 Dimensionsaregiveninmm Building in ...

Page 19: ...tial that no gaps are left in this seal in order to preventspillagenearthehob seepingintothecabinetbelow 1 Placethesealing gasketallaroundthe edge of the cut out 2 Placethehobinto the cut out and secureitbymeansof the relevant fixing clampsandscrews as showninthediagram 3 Removetheexcessseal Theedgeofthehobformsadoublesealwhichpreventstheingressof liquids FO0199 a Seal ...

Page 20: ... 3ampASTA approved BS1362 fusemustbeused Shouldtheplugneedtobereplacedfor anyreason thewiresinthemainslead arecolouredinaccordancewiththe following code GreenandYellow Earth Blue Neutral Brown Live 1 Connectthegreenandyellow earth wire to the terminal in the plug which is marked with the letter E or the earth symbol or coloured green and yellow 2 Connect the blue neutral wire to the terminal in th...

Page 21: ...nsure that the hob supply cord does not come into contact with surfaceswithtemperatureshigherthan50deg C Wiringdiagram 1 TAPSIGNITORSWITCHES 2 IGNITORUNIT 2 1 L N 0 220 240 1 2 3 4 5 N Replacementofthecable The connection of the voltage cable to the appliance s terminal block isoftype Y Thismeansthatitsreplacementrequiresthespecific equipmentofatechnician Inthiscase onlycabletypeH05RR Fmustbeused ...

Page 22: ... Electricity supply shouldnowbe satisfactory Carry out D Resistanceto Earthcheck Inlet wiring faulty Rectifyany fault Isolateapplianceand carry out B Insulationcheck Rectify any fault including replacing fusesasnecessary NO Y E S SOCKET faceview PLUG withcoverremoved EarthWire Green Yellow NeutralWire Blue FUSE E N L Brown Blue Green Yellow Green Yellow Brown Blue NO Y E S ...

Page 23: ...adsfromLtoNinapplianceterminalblock Ifmeterreads 0 thenthereisashortcircuit b metersetoný Ohm x100scale Repeat test with leads from Lto E If meter reads less than infinity there is a fault NOTE Should it be found that the fuse has failed but no fault is indicated adetailedcontinuitycheck i e bydisconnectingandcheckingeach component is required to trace the faulty component It is possible that a fa...

Page 24: ...simmer adjusted Light burner manually Check continuity from N on the mains connector block and O on the ignitor unit Check continuity from L on the mains connector block and the taps ignition switches Check continuity from ignition switches connector to ignitor unit Check continuity from the tip of each electrode to the terminals 1 to 5 on the ignitor unit Check for breaks in the insulation oftheH...

Page 25: ...2 Removethecontrolknob 3 Theadjustmentscrewislocated down the centre of the gas tap control shaft Toadjust useathinbladed screwdriverandturnthe adjustment screw until the flame issteadyanddoesnotextinguish when the knob is turned from MINtoMAX Repeatthis procedureforallburners PressureTesting 1 Remove left hand pan support and front left burner cap and crown 2 Fit manometer tube over the injector ...

Page 26: ...ctricity supply 3 Removeallpansupports burnercaps rings crownsandcontrolknobs 4 With the aid of a 7mm box spanner the burner injectors can then be unscrewedandreplacedbytheappropriateLPGinjectors TOADJUSTTHEGASRATE With the aid of a thin bladed screwdriver completely tighten down the bypassadjustmentscrew whichislocateddownthecentreofthegas tap control shaft Upon completion stick the replacement r...

Page 27: ...board monitors software tv dvd and othes Manual users user manuals user guide manual owners manual instruction manual manual owner manual owner s manual guide manual operation operating manual user s manual operating instructions manual operators manual operator manual product documentation manual user maintenance brochure user reference pdf manual ...