10
1. Depress and turn the control knob
for the burner, the left to Max. flame
2. The ignition electrode will emit
sparks, and when the mixture of gas
and air is correct, the burner will be
ignited. Is not possible to connect
the unit to mains, a match may be
used to ignite the burner
3. After starting the burner, press the
control knob for approx. 10
seconds to activate the automatic
thermo couple.
4.
Important Ignition position is at
Max flame
Ignitions
Gas installation
The appliance is factory set for
Natural Gas. Fit the gas regulator
supplied with the appliance to the gas
inlet. The location of the gas inlet is
approximately 240mm form the right
hand side of the appliance and
40mm from the back of the appliance.
The connection of the Gas Regulator
is ½” Gas female thread and the
pressure at the test point should be
adjusted to1.00kPa with the large and
simmer burners operating at
maximum.
For Universal LPG connection, the
appliance needs to be first converted
using the conversion kit and
instructions supplied with the
appliance.
15
Fixing
* Prepare the cut out according to
the "cut out measurements”.
Connect the brass extension Piece to
the bras elbow on the underside of hob.
* Screw the fixing brackets out to such
an extent that they can be turned in
under the table top.
Tighten the brackets on the to table
top with an ordinary screwdriver.