13
Gas connection
Choose fixed connections or use a flexible pipe in stainless steel in compliance
with the regulation in force.If using flexible metallic pipes, be careful they do
not come in contact with mobile parts or they are not squeezed. Use the same
attention when the hob is combinated with an oven.
IMPORTANT
- To ensure a correct operation, a saving of energy and the long-
life of the appliance, the voltage pressure of the appliance must correspond to
the recommended values. The adjustable connection is fixed to the
comprehensiveramp by means of a threaded nut G 1/2".
Interpose the sealing between the components as shown in the diagram.
Screw the parts without forcing, adjust the connection in the required direction
and tighten everything. The adjustable connection allows the feeding pipe to be
situated in the site purposefully allocated on the side of the protection box of
the hob itself (see diagram). This connection allows the overall dimensions of the
hob plus the feeding to be contained into a depth of 30 mm.
The appliance, before leaving the factory, has been tested in order to give you
the best results.
IMPORTANT
- When the final connection has been made, it is essential that a
thorough leak test is carried out on the hob and installation.
Use some soapy water,
never a flame.
A)
Ramp with ending nut
B)
Seal
C)
Adjustable connection
FO 0265
FO 0264
A)
Ramp ending with nut
B)
Adjustable connection
C)
Rigid or flexible metallic
gas pipe