7
b) For free standing: A non-metallic flexible pipe can be used
as long as it complies with current standards and the
following installation instructions are observed: the pipe
must be longer than 400 mm and shorter than 1500 mm; it
must not exceed 50°C in any point; it is not pulled or
twisted; it cannot be choked and the entire edges, sharp
corners or other similar hazards.
Before connecting the non-metallic flexible pipe, the brass adapter and gasket supplied with
the cooker and/or available form the reseller must be fitted to the pipe/gas train on
the back of the cooker. The regulator provided should be positioned between the brass
adapter and the non metallic flexible pipe.
c) A certified gas plumber must complete the installation and meet with local regulation
requirements for gas connections. Where the unit has an armour cable a certified electrician
must complete the electrical connection. The white, or neutral wire will not be used and must
be capped using a marrette.
WARNINGS:
In order to prevent tipping of the appliance, must be installed a stabilized means.
Please see the picture. The chain on the back of the range
need to be fixed to the wall
(PLEASE NOTE: The fixing hook is not provided as the type will depend on the
construction of the wall to which it will be drilled and fitted. The installer should
provide the fixing hook per customer request).