Introduction

19

Extractor version

19

Filter version

20

Electrical connections

21

Safety  warnings for electrician

21

Technic Details

23

Installation

24

Safety warnings for kitchen unit installer

24

Installation

26

Hood Operation

28

Safety warnings for user

29

Maintenance and care

30

Metal grease filter

30

Open the metal grease filter

30

Carbon filter

31

Changing the light bulb

32

Cleaning

33

Special accessories

33

Technical assistance service

33

Summary of Contents for 835 D

Page 1: ...835 D 8359 D Dunstabzugshaube Fume Extractor Hood Afzuigkap Montage und Gebrauchsanweisung Installation and Operating Instructions Montage en gebruiksaanwijzing ...

Page 2: ...nings for electrician 21 Technic Details 23 Installation 24 Safety warnings for kitchen unit installer 24 Installation 26 Hood Operation 28 Safety warnings for user 29 Maintenance and care 30 Metal grease filter 30 Open the metal grease filter 30 Carbon filter 31 Changing the light bulb 32 Cleaning 33 Special accessories 33 Technical assistance service 33 ...

Page 3: ...air is forced out through a hose fitted to the top of the hood A Fig 1 The outlet hose must have a diameter of 150 mm special accessory for the filtering version Fit the connection ring above the hood with two screws then fir an exhaustingpipelongenoughtoreachtheoutside Fig 1 If the cooking vapour is passed through an outside wall you will need an MKZ telescopic wall pipe with intake and ventilati...

Page 4: ...ivated carbon filter and passed back into the kitchen through the top outlet duct grids You will need an original AEG KF 825 activated carbon filter for the filtering function See Special Accessories Fix the deflector with two screws Ø3 5x6 5 Fig 2 Fig 2 ...

Page 5: ...plug be fitted Whenwiringtheplugensurethatallstrandsofwirearesecurelyretained ineachterminal Donotforgettotightenthemainsleadclampontheplug Electrical connections 230 V using fixed power supply line with plug Fuse rating 13 amps The unit should only be connected up by an authorized electrician See rating plate for further information It is recommended that the socket for the plug is sited above th...

Page 6: ...e for the connection for the internal house wiring and the terminations labelled LOAD are for the appliance IMPORTANT The wires of the mains lead supplied with this appliance are coloured in accordance with the following code Blue Neutral Brown Live As the colours of the flexible cord of this appliance may not correspond with the coloured markings identifying the terminals in the plug proceed as f...

Page 7: ... Depht in cm 84 117 x 89 9 x 51 5 Maximum absorbed power 185W Motor absorption 1 x 160 W Lighting 2 x 9 W Length of the cable 100 cm Fan powers speed speed in compliance with IEC 61591 Extractor version 1 218 m3 h 2 337 m3 h 3 406 m3 h i 527 m3 h Filter version 1 156 m3 h 2 240 m3 h 3 261 m3 h i 308 m3 h Flange 150 mm Ø ...

Page 8: ...ted to ventilation ducts for rooms in which fuel burning appliances are installed It is advisable to apply for authorization from the relevant controlling authority when connecting the outlet to an unused chimney flue or combustion gas duct The air outlet installation must comply with the regulations laid down by the relevant authorities When the unit is used in its extractor version a sufficientl...

Page 9: ...s to say a larger hole could reduce the performance of the extractor hood If the hood is used in its filtering function it will operate simply and safely in the above conditions without the need for any of the aforementioned measures When the hood is used in its extractor function the following rules must be followed to obtain optimal operation short and straight outlet hose keep bends in outlet h...

Page 10: ... with two screws 5 x 45 mm 9 and two wall dowels 11 on the wall close to the ceiling For exhausting version Fit the connection ring S on the top of the hood with two screws Ø 3 5 x 6 5 mm 12S then fit an exhausting pipe long enough to reach the outside 13S For recycling version Fix definitively the deflector 13K on the top of the hood with two screws Ø 3 5 x 6 5 mm 12K Prepare the electric connect...

Page 11: ...27 Fig 3 ...

Page 12: ...ensive speed indicator LED G Intensive speed ON switch This speed should be used when the concentration of cooking fumes or odours is particularly strong for example when frying cooking fish etc The fast speed will run for about 5 minutes and then return to the speed previously set automatically 1 2 or 3 or switch off if no speed was selected To turn off the fast speed before the end of the 5 minu...

Page 13: ...isk of a fat fire increases when using dirty oil It is extremely important to note that overheating can cause a fire Never carry out any flambé cooking under the hood Always disconnect the unit from the power supply before carrying out any work on the hood including replacing the light bulb take the cartridge fuse out of the fuse holder or switch off the automatic circuit breaker It is very import...

Page 14: ...nit and then pull it down and out Fig 4 Handwashing Soak grease filters for about one hour in hot water with a grease loosening cleaner then rinse off thoroughly with hot water Repeat the process if necessary Refit the grease filters when it are dry Dishwasher machine Place grease filters in dish washer Select most powerful washing programme and highest temperature at least 65 C Repeat the process...

Page 15: ...ce every four months Mounting Fig 5 Fit one carbon filter on the left and one on the right so to cover the plastic grids that protect the fan wheel then turn clockwise the central handle of the carbon filter To dismount proceed in reverse order Always specify the hood model code number and serial number when ordering replacement filters This information is shown on the registration plate located o...

Page 16: ...or any damage to the motor or any fire damage linked to inappropriate maintenance or failure to observe the above safety recommendations Changing the light bulb Disconnect the unit from the mains power supply Remove the lamp cover Always replace burnt out lamps with 9Watt max PL Fit the lamp cover on its seat If the light does not come on make sure the bulb has been screwed in correctly before con...

Page 17: ...ild up that could constitute a fire hazard Special accessories MKZ telescopic wall pipe E Nr 942 1180609 outlet hose ABS150 150 mm Ø 942 118 613 Carbon filter KFF 942 118 627 Technical assistance service You are welcome to telephone our technical assistance service see list of technical assistance centres whenever you need information or in the unlikely event of a fault When calling please be read...

Page 18: ...AEG Hausgeräte AG Postfach 1036 D 90327 Nürnberg Copyright by AEG LI084A ...