TECHNICAL DATA
A18FCN18GA / A18FCN18GANZ
Type
Brad nailer
Battery voltage
18 V
Fastener type
18GA Brad nails
Diameter
1.2 mm
Length min./max
15.9 - 54 mm
Recommended Cycle rate
900 / hour
%XUVWF\FOHUDWH$)&1*$±EXPS¿UHPRGH
1 / second
Burst cycle rate (A18FCN18GANZ)
1 / second
Magazine capacity
105 nails
Fastener range
15.9 to 54 mm
Weight without battery pack
2.45 kg
Noise Information
Measured values determined according to EN 60745. Typically, the A-weighted noise
levels of the tool are:
Sound pressure level / Uncertainty
Sound power level / Uncertainty
Wear ear protection!
L
pA
=85.5 dB (A) / K
pA
=3 dB(A)
L
WA
=96.5 dB (A) / K
WA
=3 dB(A)
Vibration Information
Vibration total values (triaxial vector sum) determined according to EN 60745.
Vibration emission value / Uncertainty
a
h
=
2.5 m/s
2
/ K=1.5 m/s
2
WARNING!
The declared vibration total values and the declared noise emission values given in this instruction manual have been measured in
accordance with a standardised test and may be used to compare one tool with another. They may be used for a preliminary assessment of
exposure.
The declared vibration and noise emission values represent the main applications of the tool. However, if the tool is used for different
applications, used with different accessories, or poorly maintained, the vibration and noise emission may differ. These conditions may
VLJQL¿FDQWO\LQFUHDVHWKHH[SRVXUHOHYHOVRYHUWKHWRWDOZRUNLQJSHULRG
An estimation of the level of exposure to vibration and noise should take into account the times when the tool is turned off or when it is
UXQQLQJLGOH7KHVHFRQGLWLRQVPD\VLJQL¿FDQWO\UHGXFHWKHH[SRVXUHOHYHORYHUWKHWRWDOZRUNLQJSHULRG
Identify additional safety measures to protect the operator from the effects of vibration and noise, such as maintaining the tool and the
accessories, keeping the hands warm (in case of vibration), and organising work patterns.
COMPATIBLE BATTERY PACKS (NOT INCLUDED)
L1820R
L1820S
A18FB2
L1825R
L1830R-X5
A18B4
L1840R
A18FB4
L1850R
A18FB5
L1860R
L1860R-X5
L1890R
Use AEG 18V battery and charger only
WARNING! Read all safety warnings, instructions,
LOOXVWUDWLRQVDQGVSHFL¿FDWLRQVSURYLGHGZLWKWKLVSRZHUWRRO
Failure to follow all instructions listed below may result in electric
VKRFN¿UHDQGRUVHULRXVLQMXU\6DYHDOOZDUQLQJVDQGLQVWUXFWLRQ
for future reference.
NAILER SAFETY WARNINGS
$OZD\VDVVXPHWKDWWKHWRROFRQWDLQVIDVWHQHUV
Careless
KDQGOLQJRIWKHQDLOHUFDQUHVXOWLQXQH[SHFWHG¿ULQJRIIDVWHQHUVDQG
personal injury.
'RQRWSRLQWWKHWRROWRZDUGV\RXUVHOIRUDQ\RQHQHDUE\
Unexpected triggering will discharge the fastener causing an injury.
'RQRWDFWXDWHWKHWRROXQOHVVWKHWRROLVSODFHG¿UPO\DJDLQVW
WKHZRUNSLHFH
If the tool is not in contact with the workpiece, the
IDVWHQHUPD\EHGHÀHFWHGDZD\IURP\RXUWDUJHW
'LVFRQQHFWWKHWRROIURPWKHSRZHUVRXUFHZKHQWKHIDVWHQHU
MDPVLQWKHWRRO
While removing a jammed fastener, the nailer may
be accidentally activated if it is plugged in.
8VHFDXWLRQZKLOHUHPRYLQJDMDPPHGIDVWHQHU
The mechanism
may be under compression and the fastener may be forcefully
discharged while attempting to free a jammed condition.
'RQRWXVHWKLVQDLOHUIRUIDVWHQLQJHOHFWULFDOFDEOHV
It is
not designed for electric cable installation and may damage the
LQVXODWLRQRIHOHFWULFFDEOHVWKHUHE\FDXVLQJHOHFWULFVKRFNRU¿UH
hazards.
ADDITIONAL SAFETY WARNINGS
The product is designed for single-hand use. Do not hold the
product by the front of the magazine. Do not put hands, head, or
other parts of your body near the bottom of the magazine where
the fastener exits the product, as serious personal injury could be
caused.
Always ensure that the workpiece contact is fully positioned above
the workpiece. Positioning the workpiece contact only partially
above the workpiece could cause the fastener to miss the workpiece
completely and result in serious personal injury.
Do not drive fasteners near edge of material. The workpiece may
split causing the fastener to ricochet, injuring you or a coworker. Be
aware that the fastener may follow the grain of the wood, causing
it to protrude unexpectedly from the side of the work material or
GHÀHFWSRVVLEO\FDXVLQJLQMXU\
Keep hands and body parts clear of immediate work area. Hold
workpiece with clamps when necessary to keep hands and body out
of potential harm. Be sure the workpiece is properly secured before
pressing the fastener against the material. The workpiece contact
may cause the work material to shift unexpectedly.
Keep face and body parts away from back of the tool cap when
working in restricted areas. Sudden recoil can result in impact to the
body, especially when nailing into hard or dense material.
During normal use the product will recoil immediately after driving a
fastener. This is a normal function of the product. Do not attempt to
prevent the recoil by holding the nailer against the work. Restriction
to the recoil can result in a second fastener being driven from the
Summary of Contents for A18FCN18GA
Page 1: ...A18FCN18GA A18FCN18GANZ Original instructions ...
Page 4: ...4 10 12 11 8 11 ...
Page 5: ...5 START 9 9 10 10 6 For A18FCN18GA only ...
Page 7: ...7 75 100 50 75 25 50 0 25 ...
Page 8: ...8 2 1 2 2 1 1 ...
Page 9: ...9 1 2 2 1 1 START 2 3 4 For A18FCN18GA only ...
Page 10: ...10 1 1 2 ...
Page 11: ...11 1 2 3 ...
Page 12: ...12 1 2 2 3 1 3 2 1 2 3 1 ...
Page 13: ...13 2 4 1 ...
Page 17: ......
Page 18: ......
Page 19: ......