background image

7

7

to instruct others who may use this product. If you loan someone 
this product, loan them these instructions also.

 

The machine shall be connected to a circuit protection device 
(fuse or circuit breaker).

 

Operate the machine from the front of the control panel.

 

When the machine is in operation, many parts of machine may 
cause a high temperature. Use necessary personal protection 
equipment such as gloves to avoid injuries resulting from a high 
temperature.

 

When using the product with an extension cord, use a 3*1.0 mm

2

 

heavy duty extension cord only.

 

This machine is not intended for use by persons (including 
children) with reduced physical, sensory or mental capabilities, or 
lack of experience and knowledge, unless they have been given 
supervision or instruction concerning use of the appliance by a 
person responsible for their safety. Children should be supervised 
to ensure that they do not play with the machine.

RESIDUAL RISKS

Even when the product is used as prescribed, it is still impossible 
to completely eliminate certain residual risk factors. The following 
hazards may arise and the operator should pay special attention to 
avoid the following:

 

Use the product only for its intended use. Do not alter or modify 
the product from the original design or function.

 

Always be aware that misuse and improper handling of the 
product can cause injury to yourself and others.

 

Never leave an air compressor unattended with the hose attached 
to a tool.

 

Do not continue to use an air compressor or hose which leaks air 
or does not function properly.

 

Risk of bursting

 

Do not adjust regulator to result in output pressure greater 
than marked maximum pressure of attachment.

 

Heat and high temperature are generated while motor and 
cylinder are running. Touching exposed metal can result in 
serious burns.

 

Always keep the air compressor away from the working zones.

 

Injury casued by noise

 

Wear ear protection.

 

The gas from air compressor can propel dirt, chips, loose particles 
and small objects at high speed. This may result in objects being 
thrown into eyes or other possible serious injury.

 

Always wear proper personal protective equipment when 
operating different tools.

 

WARNING!

 Do not remove the NITTO couplers on the product. 

Altering the NITTO style couplers which are fixed and sealed on the 
product will void your warranty. If you would like to use alternative 
style fittings, please use an adaptor for the application.

SPECIFIED CONDITIONS OF USE

This compressor is designed to supply pressurised air only. It must 
not be used to compress any other gas. It is designed to operate air 
powered tools. The compressor should be operated indoors only.

UNPACKING

Carefully remove the product and any accessories from the box.

 

WARNING!

 Inspect the product carefully to make sure no 

breakage or damage occurred during shipping. Do not discard the 
packing material until you have carefully inspected and satisfactorily 
operated the product.

 

WARNING!

 If any parts are damaged or missing do not operate 

the product until the parts are replaced. Use of the product with 
damaged or missing parts could result in serious personal injury.

 

WARNING!

 Do not attempt to modify the product or create 

accessories not recommended for use with the product. Any such 
alteration or modification is misuse and could result in a hazardous 
condition leading to possible serious personal injury.

Packing list

 

Air compressor

 

Operator’s manual

OPERATION

 

DANGER!

 Do not disassemble the Nitto couplers, check valve, 

tank drain valves or safety relief valve with air in tank — bleed tank.

 

WARNING!

 Always wear eye protection with side shields. Failure 

to do so could result in objects being thrown into your eyes resulting 
in possible serious injury.

 

WARNING!

 Do not attach any tools to the open end of the hose 

until start-up has been completed.

 

WARNING!

 The solenoid valve releases pressure when the air 

compressor reaches the maximum pressure. The LED of the solenoid 
valve should light up normally when it is powered on. Keep the 
solenoid valve clean, and do not block the vent with debris. User is not 
allowed to remove or modify the solenoid nut.

 

CAUTION!

 Do not use in an environment that is dusty or 

otherwise contaminated. Using the air compressor in this type of 
environment may cause damage to the unit.

ATTACHING/DISCONNECTING AIR HOSE

See figure 1.

NOTE:

 For operation using pressures above 6 bar, 

 

(87 psi) delivery hoses should be fitted with a safety cord, e.g., wire 
rope.
1.  Make sure the air compressor is off and unplugged.
2.  Rotate pressure regulator knob fully counterclockwise.
3.  Confirm that the outlet pressure is at zero (0) bar.
4.  Attach hose with quick connect air fitting to 6.35 mm (1/4 in.) 

quick connect coupler (regulated pressure) on air compressor. 

Make sure to push the hose adapter end fully into the coupler 

until the sleeve springs forward to lock it in place.

To disconnect an air hose or an air tool:

1.  Rotate pressure regulator knob fully counterclockwise. 
2.  Confirm that the outlet pressure is at zero (0) bar.
3.  When disconnecting a hose from quick coupler, always firmly hold 

the release end of hose.

4.  Pull back on the release sleeve on the quick coupler.
5.  With a firm grip, pull out the quick connect air fitting that is 

attached to the quick coupler.

Summary of Contents for AC756S

Page 1: ...AC756S Original instructions ...

Page 2: ...2 2 Important It is essential that you read the instructions in this manual before assembling operating and maintaining the product Subject to technical modifications ...

Page 3: ...f switch 2 Tank pressure gauge 3 Pressure regulator knob 4 Carrying handle 5 Regulated pressure gauge 6 Quick connect coupler 7 Tank 8 Drain valve 9 Rubber foot x4 10 Safety valve 11 Cord wrap hook x2 12 Power cord 13 Solenoid valve 14 Air filter ...

Page 4: ...re regulator knob 4 Turn counterclockwise to decrease air pressure 5 Air hose 1 Air filter housing 2 Air filter 3 Air filter cover 1 Drain valve 2 Open position 3 Closed position 1 Safety valve 2 Rotate counterclockwise to release pressure 3 Rotate clockwise to close 1 2 5 1 4 3 Fig 1 Fig 2 Fig 3 Fig 4 Fig 5 Fig 6 1 2 1 2 3 1 3 3 2 2 1 ...

Page 5: ...areas and benches invite accidents Do not leave tools or pieces of wood on the tool while it is in operation Do not use in dangerous environments Do not use power tools in damp or wet locations or expose to rain Keep the work area well lit Keep children and visitors away All visitors should wear safety glasses and be kept a safe distance from work area Do not let visitors contact tool or extension...

Page 6: ...oors Inspect tank yearly for rust pin holes or other imperfections that could cause it to become unsafe Never weld or drill holes in the air tank Never use the air compressor with the guard removed Make sure the hose is free of obstructions or snags Entangled or snarled hoses can cause loss of balance or footing and may become damaged Use the air compressor only for its intended use Do not alter o...

Page 7: ...ust not be used to compress any other gas It is designed to operate air powered tools The compressor should be operated indoors only UNPACKING Carefully remove the product and any accessories from the box WARNING Inspect the product carefully to make sure no breakage or damage occurred during shipping Do not discard the packing material until you have carefully inspected and satisfactorily operate...

Page 8: ... Failure to heed this warning could result in death or serious personal injury The pressure relief valve will automatically release air if the air tank pressure exceeds the preset maximum and will stop releasing air once the tank pressure drops to within the preset minimum 1 Turn the air compressor on and allow the tank to fill The compressor will shut off when the pressure reaches the preset maxi...

Page 9: ...come in contact with plastic parts Chemicals can damage weaken or destroy plastic which may result in serious personal injury REPLACING THE AIR FILTER See figure 6 Follow the instructions below to replace the air filter Normal environment Check and clean the filter once a month Replace the filter if damaged or heavily clogged Heavy dust environment Check and clean the filter once a week Replace th...

Page 10: ...ing area as possible Keep compressor at least 10 m from the spraying area and all explosive vapours Caution risk of electric shock Do not dispose of electric tools together with household waste material Electric tools and electronic equipment that have reached the end of their life must be collected separately and returned to an environmentally compatible recycling facility ...

Page 11: ... Check with voltmeter Lack of proper ventilation room temperature too high Move compressor to well ventilated area Wrong gauge wire or length of extension cord Check for proper gauge wire and cord length Air tank pressure drops when compressor shuts off Loose connections fittings tubing etc Check all connections with soap and water solution and tighten Loose drain valve Tighten drain valve Check v...

Page 12: ... 3 4 5 6 7 8 9 11 12 15 16 17 19 20 21 22 23 24 26 27 28 29 30 31 32 34 35 36 37 38 39 40 10 18 41 44 25 66 67 68 69 70 65 63 61 60 71 45 46 47 50 51 48 49 52 53 54 72 78 33 13 14 42 43 58 59 57 56 79 83 82 81 80 84 85 86 87 PARTS LIST ...

Page 13: ...el 75 Nut 10 Air filter 32 Protection ring 54 Nut 76 Cushion foot 11 Obturating ring 33 Bolt 55 High pressure pipe 77 Bolt 12 Cylinder head 34 Bolt 56 Capacitor 78 Power line 13 Protection cover 35 Spring washer 57 Bolt 79 Protective circle 14 Bolt 36 Stator 58 Protection ring 80 Iron plate 15 Bolt 37 Nut 59 Capacitor cover 81 Bolt 16 Obturating ring 38 Rotator 60 Electrical wire 82 Thread buckle ...

Page 14: ......

Page 15: ......

Page 16: ...htronic Industries N Z Limited Unit C 70 Business Parade South Highbrook Auckland 2013 New Zealand www aegpowertools com au www aegpowertools co nz AEG is a registered trade mark used under license from AB Electrolux publ NITTO is a registered trade mark owned by Nitto Kohki Co Ltd 20210813v1 ...