--------------------------------------------------------------------------------13/20--------------------------------------------------------------------------------
instruction:
INIT <CR>
answer:
ok <CR>
4.6
Saving of the parameters
The instruction VSAVE is used to store the actual parameters to the EEPROM.
instruction:
VSAVE <CR>
answer:
ok <CR>
4.7
Changing the baudrate
With this instruction you can change the baudrate of the AMP 4/8. The default setting is 2 (19200
baud). This instruction has to be saved with the instruction VSAVE. The AMP 4/8 is effected after a
warmstart (RST) or coldstart. If there are different settings in the AMP and the host PC it is not
possible to communicate.
instruction:
BD <SP> 2 <CR>
answer:
2 <CR>
The possible baudrates are:
0
4800 baud
1
9600 baud
2
19200 baud
3
38400 baud
4.8
Warmstart with saved parameters
This instruction reboots the AMP 4/8 with the saved parameters.
instruction:
RST <CR>
answer:
<CR>