What to do if ...
28
Symptoms
Appliance does not work,
no pilot light is
illuminated.
Possible Cause
Appliance is not switched
on.
Mains plug is not plugged
in or is loose.
Fuse has blown or is
defective
Socket is defective.
Mains malfunctions are to
be corrected by an
electrician.
Remedy
Switch on the appliance.
Insert mains plug.
Check fuse, replace if
necessary.
The compressor runs
continuously
Green light does not light
up, yellow light lights up
when the fast freeze func-
tion is activated.
Green light faulty.
Please inform your local
Service Force Centre.
Yellow light does not light
up, when the fast freeze
function is activated,
appliance is on.
Yellow light faulty.
Please inform your local
Service Force Centre.
Temperature is set too
cold.
Turn the thermostat con-
trol knob to a warmer set-
ting temporarily.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not airtight
(possibly after reversing
the door).
Carefully warm the leaking
sections of the door seal
with a hair dryer (on a
cool setting). At the same
time shape the warmed
door seal by hand such
that it sits correctly.