If after the above checks there is still a fault, call your local AEG Service
Force Centre.
In-guarantee customers should ensure that the above checks have been
made as the engineer will make a charge if the fault is not a
mechanical or electrical breakdown.
Please note that proof of purchase is required for in-guarantee service
calls.
Noises during Operation
The following noises are characteristic of refrigeration appliances:
•
Clicks
Whenever the compressor switches on or off, a click can be heard.
•
Humming
As soon as the compressor is in operation, you can hear it humming.
•
Bubbling/Splashing
When refrigerant flows into thin tubes, you can hear bubbling or
splashing noises. Even after the compressor has been switched off,
this noise can be heard for a short time.
Heavy build up of frost,
possibly also on the door
seal.
Door seal is not air tight
(possibly after changing
over the hinges).
Carefully warm the leak-
ing sections of the door
seal with a hair dryer (not
hotter than approx. 50 °C).
At the same time shape the
warmed door seal by hand
such that it sits correctly.
The compressor does not
start immediately after
changing the temperature
setting or pushing the fast
freeze button.
This is normal, no error has
occurred.
The compressor starts after
a period of time.
Noise
Appliance is not level.
Readjust the front levelling
feet.
Appliance is in contact
with wall or other objects.
Push appliance away a
short distance.
A part at the back of the
appliance, e.g. a tube, is in
contact with another
appliance part or the wall.
Bend this part away care-
fully if necessary.
Symptom
Possible Cause
Solution