Prepare the solution as indicated on
the packaging of the descaling product
supplied with the coffee maker:.
Pour the contents of the bottle of des-
caler (approx. 0.125 litres) into the
water tank and then add 1 litre water.
1
Important: Do not under any circum-
stances use any descalers which are not
recommended by AEG/Electrolux. If
other descaling agents are used, AEG/
Electrolux accepts no liability for any
damage. You can obtain descaling liq-
uid from specialist retailers or from the
AEG/Electrolux Service Line.
0
Place a container with a minimum
capacity of 1.5 litres under the milk
frother (Fig. 6).
0
Press and hold the
button for at
least 5 seconds. The
light
switches on to indicate the start of the
descaling program (the
and
lights remain off to indicate that it is
not possible to make coffee).
0
Turn the steam knob half a turn anti-
clockwise (Fig. 8). The descaling solu-
tion will come out of the milk frother
and start to fill the container under-
neath.
0
The descaling program automatically
performs a series of deliveries and
pauses, so as to remove the lime scale
deposits from inside the coffee maker.
0
After around 30 minutes, when the
light comes on, turn the steam knob
half a turn clockwise (Fig. 8) until it
stops.
The machine must be rinsed so as to
eliminate the residues of descaling
solution from inside the machine.
0
Remove the water tank, rinse it and fill
it with clean water.
0
Reposition the tank.
0
Empty the collection container
(located under the milk frother) that is
full of liquid, and then replace it under
the milk frother.
0
Turn the steam knob half a turn anti-
clockwise (Fig. 8). Hot water will come
out of the milk frother and fill the con-
tainer underneath.
0
When the tank is empty, the
light goes off and the
light comes
on.
0
Turn the steam knob all the way clock-
wise (Fig. 8) and fill the water tank
with clean water again.
The program of descaling is now termi-
nated and the machine is ready to do
again the coffee.
3
Note:
if the descaling procedure is
stopped before completion, the
alarm is not deactivated and the pro-
cedure must be started again from the
beginning.
1
Important: the guarantee is not valid
if the above descaling operation is
not performed regularly.
9.5
Setting the water hardness
The
light switches on after a
preset period of operation, set in the
factory, considering the maximum
quantity of lime scale that may be
contained in the mains water. If neces-
sary, this period of operation can be
extended, thus making the descaling
operation less frequent, by program-
ming the machine based on the actual
lime content in the water used. You
can use the enclosed test strip to
determine the water hardness, or con-
tact your local water supply company.
Determining water hardness
0
Dip the test strip in cold water for
around 1 second. Shake off the excess
water, and gauge the hardness by
means of the pink bands.
No
pink bands or
one
pink band:
Hardness level 1, soft
up to 1.24 mmol/l, or
up to 7° German hardness, or
up to 12.6° French hardness
Two
pink bands:
Hardness level 2, medium hard
up to 2.5 mmol/l, or
up to 14° German hardness, or
up to 25.2° French hardness
822_949_352 CS5200.book Seite 38 Mittwoch, 9. Mai 2007 7:26 19
Summary of Contents for CS 5 SERIES
Page 2: ...2 1 L A O N M H E F G K C J B D A O N CS 5000 CS 5200 ...
Page 3: ...3 2 R X T W S P V U Z Y Q R P Q X W CS 5000 CS 5200 ...
Page 4: ...4 3 4 5 6 7 b a e g d c h f n m l k j o p q ...
Page 5: ...5 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 ...
Page 6: ...6 24 25 26 27 28 29 30 31 32 33 32 34 b c d f e a 5 ...