5
ENGLISH
4.2
Charcoal filter
Type 20 LONG LIFE - Washable activat-
ed charcoal fi lter
The charcoal fi lter can be washed once every
two months using hot water and a suitable
detergent, or in a dishwasher at 65°C (if
the dishwasher is used, select the full cycle
function and leave dishes out).
Eliminate excess water without damaging the
fi lter, then remove the mattress located inside
the plastic frame and put it in the oven for 10
minutes at 100° C to dry completely. Replace
the mattress every 3 years and when the cloth
is damaged.
4.3 Type 15 - NON-washable activated
charcoal fi lter
The saturation of the
charcoal fi lter
occurs
after more or less prolonged use, depending
on the type of cooking and the regularity of
cleaning of the grease fi lter. In any case it is
necessary to replace the cartridge at least
every four mounths.
The charcoal fi lter may NOT be washed or
regenerated.
(1*)
(2*)
(3**)
(4**)
(*) Type 20
(**) Type 15 - Type 20
4.4 Regenerable carbon
fi
lter
The carbon
fi
lter must be regenerated every
two months (or when the
fi
lter saturation indica-
tor - if present - indicates the need for it) and in
accordance with the procedure as shown here
below:
1.
Disconnect the electrical appliance from the
mains.
2.
Clean the
fi
lter’s surface with a damp cloth
to remove grease deposits.
3.
Put the
fi
lter in an oven at 200 degrees for
45 minutes.
4.
Turn off the oven and wait for an hour
before taking out the
fi
lter.
Attention!
Make sure the
fi
lter has cooled
down before touching it.
Type SUPCHARC-E