31
Table 3
5.
Specification and application areas
for contractors
5.1
Specification
(The details on the type plate apply)
Type
DDLT
PinControl 13
DDLT
PinControl 18
DDLT
PinControl 21
DDLT
PinControl 24
Rated output
kW
13.5
18
21
24
Rated current
A
19.5
26
30.3
34.6
Heating output
Stage
kW
kW
I
4.6
6.8
II
10.6
13.3
I
6.3
9.2
II
14.3
18.0
I
7.4
10.8
II
16.8
21.1
I
8.3
12.2
II
19.0
23.8
Starting volumes
Stage
or
l/min
I
2.4
II
3.9
I
3.0
II
4.9
I
3.5
II
5.6
I
4.1
II
6.3
Throughput limit
l/min
4.7
5.9
7.0
7.8
Pressure at starting volume
Stage
MPa
II
0.09
II
0.11
II
0.13
II
0.15
Rated capacity
0.4 l
Type
sealed
Rated operating pressure
1 MPa (10 bar)
Weight
3.6 kg
Protection class to EN 60335
1
Protection level to EN 60529
IP 25
Test symbols
see equipment type plate
Building Regulation test
certificate [Germany]
PA-IX xxxx/I applied for
Water connection (male thread)
G ½"
Power connection
3/PE ~ 400 V - 50/60 Hz
Bare wire heating system
900
Ω
cm (see Table 4)
Cold water inlet temperature
max. 25 °C
Applications
water with low limescale levels and with limescale content
5.2
Application areas
Specific electrical resistance and specific electrical conductivity
A general test certificate [Germany] as verification of suitability regarding
noise emissions has been issued for the instantaneous water heater series
DDLT PinControl based on the State Building Regulations [Germany].
DIN 4109
PA-IX xxxx/I
AEG
Table 4
For contractors
Details as
application ranges for different reference temperatures
Standard details
at 15 °C
at 20 °C
at 25 °C
Resistance
Conductivity
Conductivity
Ω
cm
mS/m
µS/cm
≥
900
≤
111
≤
1110
≥
800
≤
125
≤
1250
≥
735
≤
136
≤
1360