background image

78

Installing the front panel (see also “Special accessories”)
• Remove first the rear then the front grease filters.
• Remove the internal cover pressing both unlocking devices (press

and pull). Fig. 12.

• Predrill the front panel as per template and fix it to the vapour catcher

with 3 screws. Fig. 13-14.

• Clip the Internal cover back in and insert both grease filters (first the

front one and then the rear one).

Fig. 12

Fig. 14

Fig. 13

Summary of Contents for DF 6260

Page 1: ...DF 6260 Köksfläkt Ventilator Liesituuletin Emhætte Cooker Hood Instruktionsbok Bruksanvisning Käyttöohje Brugsvejledning Operating and Installation Instructions ...

Page 2: ...ects Keep this instruction booklet in a safe place this booklet should always accompany the appliance at such time as it is sold or given to other persons for use Installation and service Any electrical installation of the cooker hood must be carried out by a qualified electrician and the hood itself must be installed by someone with experience Installation made by an unqualified person can lead t...

Page 3: ...ker hood It can cause a fire Remember that overheated fat may spontaneously ignite Never leave the frying pan unattended It is essential that the grease filter is regularly cleaned to help avoid fat dripping on to the hot zone and causing a fire Read the section on Maintenance and Cleaning in the instruction book Disposal Prevent accidents when disposing of your cooker hood Disconnect the power pl...

Page 4: ...pliances are installed A Switches Motor light B Grease filter C Light D Control panel E Vapour catcher Extractible Accessories The following are included with the cooker hood 1 hood canopy complete with controls lighting and fan motor 1 Adaptor Ø 150 mm 1 plastic bag containing documentation screws to fix the hood The following can be ordered from your retailer Charcoal filter KFL 60 80 should be ...

Page 5: ...al conditions and high speed when odours are more concentrated Turn the hood on a few minutes before you start cooking then you will get an underpressure in the kitchen It should be left on after cooking for about 15 minutes or until all odours have disappeared Correct ventilation If the cooker hood is to work correctly there must be an underpressure in the kitchen It is important to keep the kitc...

Page 6: ...ng a damp cloth and a mild detergent Never use corrosive abrasive or flammable cleaning products Cleaning the grease filters Clean the filter every month or every other month according to how much the hood is used The cleaner the filters the more grease they collect To remove the filters Fig 4 Pull the lock outwards and extract the grease filter Fig 4 The filter is made of aluminium wires on which...

Page 7: ...The activated carbon filter must normally be replaced at least once every year This filter cannot be washed or regenerated To guarantee proper absorption of odours the working volume of the activated carbon must be proportionate to the hood air flow In this case the high quality of the activated carbon will ensure efficient odour removal for approximately one year assuming that the hood is used no...

Page 8: ...o the left and fold down the bulb cover Fig 4 Replace the old light bulb s with a new light bulb of the same kind Close the bulb cover and relock it by twisting the bolts to the right If the light does not come on make sure the bulb has been inserted in correctly before contacting the technical assistance service Fig 4 Fig 4 D ...

Page 9: ...ppliance is handed over to the first retail purchaser which must be verified by purchase invoice or similar documentation The guarantee does not cover commercial use 2 The guarantee covers all parts or components which fail due to faulty workmanship or faulty materials The guarantee does not cover appliances where defects or poor performance are due to misuse accidental damage neglect faulty insta...

Page 10: ...a The product is installed and used in accordance with our instructions and is only used domestically i e a normal household The product is installed taking into account regulations in your new country Before you move please contact your nearest Customer Care centre listed below to give them details of your new home They will then ensure that the local Service Organisation is aware of your move an...

Page 11: ...erial so that it is out of the way of small children Position The cooker hood should be mounted freely hanging on the wall The cooker hood must be at least 47 cm above electric hobs or electric ranges or at least 65 cm above gas burners or gas ranges The cooker hood cannot be connected to flues of other appliances that run on energy sources other than electricity Please keep to the provisions of o...

Page 12: ...e roof of the wall unit see Fig 5 This hole is to allow passage of the outlet pipe and the power cable and to facilitate servicing The wall unit must have a minimum body depth without door of 300 mm with recessed light screen and min 370 mm with flush mounted light screen The unobstructed internal height must be at least 370 mm 190 238 172 Fig 5 ...

Page 13: ...e deflector to the flange Fig 6b Spice rack If a spice rack is to be incorporated in front of the hood a minimum distance of 5 mm must be provided between the front edge of the fume extractor hood and the spice rack wall this air gap being necessary for air circulation The upper part of the spice rack rear wall should be detachable access for exhaust air hose or adjustment of furniture housing Fig...

Page 14: ...e hood Important Detach and insert the grease filters only when the vapour catcher is fully withdrawn Remove the grease filters First remove the rear and then the front grease filter For 19 mm side walls the spacer discs clipped in on the appliance body must be taken out Mount the hood with 4 x Ø 4 mm screws Fig 7 Insert the hood in the furniture housing and engage both mounting claws installation...

Page 15: ...ccessories Apply pressure Fig 8 Fitting the charcoal filter for filter version If the fume extractor hood is installed as a return air appliance Filter version air outlet above the wall unit the charcoal filter special accessory must be fitted before the grease filters are fitted Installation sequence 1 Insert the holding frame for the charcoal filter in the shaft of the hood with the 2 lugs facin...

Page 16: ...nting claws installation aids place a max 3 mm dia Phillips screw driver in the spring opening and simultaneously press the springs inwards towards the appliance housing Fig 10 Important Hold the hood firmly Adjusting the extractor part E Fig 1 Fig 11 On wall units with a body depth of 275 mm to 335 mm the vapour catcher depth can be adjusted as follows Remove both grease filters Loosen the screws...

Page 17: ...ters Remove the internal cover pressing both unlocking devices press and pull Fig 12 Predrill the front panel as per template and fix it to the vapour catcher with 3 screws Fig 13 14 Clip the Internal cover back in and insert both grease filters first the front one and then the rear one Fig 12 Fig 14 Fig 13 ...

Page 18: ...79 ...

Page 19: ...AEG Hausgeräte GmbH Postfach 1036 D 90327 Nürnberg http www aeg hausgeraete de Copyright by AEG LI1YSB Ed 05 02 ...