4. CONTROLS
Button Function
Led
L
Turns the lights on/off at maximum strength.
-
T1
Turns the motor on/off at speed one.
-
T2
Turns the Motor on at speed two.
Fixed
Press and hold the button for approximately 3 seconds, with all the loads
turned off (Motor and Lights), to turn the Activated Charcoal Filter alarm
on. The relevant LED flashes twice to confirm.
To turn the alarm off, press the button again and hold for at least 3 seconds.
The relevant LED flashes once.
Flashing
T3
Turns the Motor on at speed three.
Fixed
Press and hold the button for approximately 3 seconds, with all the loads
turned off (Motor and Lights), to perform a reset. The LED
S1
flashes
three times.
Flashing
T4
Turns the Motor on at
INTENSIVE
Speed.
This speed is timed to run for 6 minutes. At the end of this time, the system
returns automatically to the speed that was set before. If it is activated with
the motor turned off, the hood will switch to OFF at the end of the time.
It is disabled by pressing
T4
or
T1
to turn off the motor.
Flashing
Press and hold for 3 seconds to enable the remote control, indicated by
the LED flashing twice.
Press and hold for 3 seconds to disable the remote control, indicated by
the LED flashing just once.
Flashing
S1
Signals the Metal Grease Filter saturation alarm, indicating that it is
necessary to wash the filters. The alarm is triggered after the Hood has
been in operation for 100 working hours.
Fixed
When this is activated, it signals the Activated Charcoal Filter saturation
alarm, indicating that the filter must be changed; the Metal Grease Filters
must also be washed. The Activated Charcoal Filter saturation alarm comes
into operation after the Hood has been working for 200 hours.
Flashing
5. LIGHTING
• For replacement contact technical
support (“To purchase contact techni-
cal support”).