background image

8

www.aeg.com

4. CONTROLS

Button Function

Led

L

Turns  the  lights  on/off  at  maximum  strength.

-

T1

Turns  the  motor  on/off  at  speed  one.

-

T2

Turns the Motor on at speed two.

Fixed

Press and hold the button for approximately 3 seconds, with all the loads 

turned  off  (Motor  and  Lights),  to  turn  the Activated  Charcoal  Filter  alarm 

on. The  relevant  LED  flashes  twice  to  confirm.

To turn the alarm off, press the button again and hold for at least 3 seconds. 

The  relevant  LED  flashes  once.

Flashing

T3

Turns the Motor on at speed three.

Fixed

Press and hold the button for approximately 3 seconds, with all the loads 

turned  off  (Motor  and  Lights),  to  perform  a  reset.  The  LED 

S1

  flashes 

three times.

Flashing

T4

Turns the Motor on at 

INTENSIVE

 Speed.

This speed is timed to run for 6 minutes. At the end of this time, the system 

returns automatically to the speed that was set before. If it is activated with 

the  motor  turned  off,  the  hood  will  switch  to  OFF  at  the  end  of  the  time.

It is disabled by pressing 

T4

 or 

T1

  to  turn  off  the  motor.

Flashing

Press and hold for 3 seconds to enable the remote control, indicated by 

the  LED  flashing  twice.

Press and hold for 3 seconds to disable the remote control, indicated by 

the  LED  flashing  just  once.

Flashing

S1

Signals the Metal Grease Filter saturation alarm, indicating that it is 

necessary  to  wash  the  filters.  The  alarm  is  triggered  after  the  Hood  has 

been in operation for 100 working hours.

Fixed

When this is activated, it signals the Activated Charcoal Filter saturation 

alarm, indicating that the filter must be changed; the Metal Grease Filters 

must also be washed. The Activated Charcoal Filter saturation alarm comes 

into operation after the Hood has been working for 200 hours.

Flashing

5. LIGHTING

•  For replacement contact technical 

support (“To purchase contact techni-

cal support”).

Summary of Contents for DGE7670HB

Page 1: ...tilização Exaustor PT Libretto di uso Cappa IT Användningshandbok Köksfläkt SV Bruksveiledning Kjøkkenvifte NO Käyttöohjeet Liesituuletin FI Brugsvejledning Emhætte DA Руководство по эксплуатации Вытяжка RU ET Kasutusjuhend Pliidikumm LV Lietošanas pamācība Nosūcējs LT Naudotojo vadovas Gartraukis UK Інструкція з експлуатації Витяжка Használati útmutató Szagelszívó HU DGE7670HB DGE7970HB ...

Page 2: ... it Visit our website for Get usage advice brochures trouble shooter service information www aeg com Register your product for better service www registeraeg com Buy Accessories Consumables and Original spare parts for your appliance www aeg com shop CUSTOMER CARE AND SERVICE Always use original spare parts When contacting our Authorised Service Centre ensure that you have the following data avail...

Page 3: ...on The minimum safety distance between the cooker top and the extractor hood is 650 mm some models can be installed at a lower height please refer to the paragraphs on working dimensions and installation If the instructions for installation for the gas hob specify a greater distance this must be respected Checkthatthemainsvoltagecorrespondstothatindicated on the rating plate fixed to the inside of...

Page 4: ...uthorities WARNING Before installing the Hood remove the protective films Use only screws and small parts in support of the hood WARNING Failure to install the screws or fixing device in accordance with these instructions may result in electrical hazards Do not look directly at the light through optical devices binoculars magnifying glasses Do not flambè under the range hood risk of fire This appl...

Page 5: ...actor the operation of flued gas appliances should be tested by a competent person to ensure that back flow of combustion gases does not occur The symbol on the product or on its packaging indi cates that this product may not be treated as household waste Instead it shall be handed over to the applicable collection point for the recycling of electrical and elec tronic equipment By ensuring this pr...

Page 6: ...to a circuit that is regularly switched on and off by the utility ELECTRICAL CONNECTION Check that the installation complies with standards of local gas and electricity authorities If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similarly qualified person in order to avoid a hazard Ensure that the plug is accessible after installation ACCESSORIES Whe...

Page 7: ...y 2 months of operation or more frequently for particularly heavy usage and can be washed in a dishwasher Z Clean the hood using a damp cloth and a neutral liquid detergent 2 USE The extractor hood has been designed exclusively for domestic use to eliminate kitchen smells Never use the hood for purposes other than for which it has been designed Never leave high naked flames under the hood when it ...

Page 8: ...m returns automatically to the speed that was set before If it is activated with the motor turned off the hood will switch to OFF at the end of the time It is disabled by pressing T4 or T1 to turn off the motor Flashing Press and hold for 3 seconds to enable the remote control indicated by the LED flashing twice Press and hold for 3 seconds to disable the remote control indicated by the LED flashi...

Page 9: ......

Page 10: ......

Page 11: ......

Page 12: ...www aeg com shop 991 0xxx xxx_01 220221 D0000xxxx_00 ...

Reviews: