74
DK 9960 - DK 9990
A -
ON (stand-by - illuminated key) / OFF push button.
Press once or more to obtain the function desired:
Stand-by
(illuminated push button): the hood is ready to function,
the safety procedure is activated (see under – “safety procedu-
re”).
OFF: all the functions are switched off except the illumination.
B -
Speed selection push button (extraction power).
Press this push button once or more to select the most suitable
extraction speed (power) (1-2-3-i).
Attention: the i (intensive) speed is limited to 5 minutes after
which the system automatically sets itself to speed 2.
C -
The display indicates the selected extraction power (1-2-3-i) and
signals the saturation of the filters (F).
D -
Manual function selection push button (OFF)/automatic
(sensors – ON).
In automatic function (ON) the hood enters into function
(extraction) on the basis of the change in the normal
environmental conditions that the hood notices through its
sensors.
The display shows the extraction speed (power) set.
Attention! The hood is equipped with an automatic system that
establishes what the normal environmental conditions are.
In the case of abnormal operation, calibration can be carried out
manually:
Manual calibration
Carry out manual calibration in the following cases:
When the hood is installed for the first time.
When power is cut off for many hours or days (e.g. during
prolonged holidays).
When a very rapid change in temperature and/or humidity in the
kitchen takes place.
SENSOR
A
B
C
D
E